EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Performance of Partially Concrete Filled C-purlin Beam-Slab System: Numerical Investigation

Alyaa A. Al-Attar, Ahmed W. Al Zand, Mohammed Ch. Liejy, Azrul A. Mutalib, Idan I. Ghdhban

NTU Journal of Engineering and Technology · 01.03.2026 · 5 (1) · 271-279

DOI: 10.56286/ne4ntb77 ↗

Kurz gefasst

Fachartikel in der Zeitschrift NTU Journal of Engineering and Technology, online erschienen am 01.03.2026. Verfasst von Alyaa A. Al-Attar und 4 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Lightweight cold-formed steel beams are widely utilized in roofing systems. Recently, engineers have increasingly used concrete-filled cold-formed steel tube beams for flooring systems due to their sufficient structural performance. A system that uses cold-formed steel beam sections with dry-board profile steel sheet slab (CBPDS) system would cost less than the conventional I-steel beam-slab system, with less self-weight, it is considered one of the types of sustainable buildings. This study numerically investigated the structural performance of the newly suggested composite beam-slab (CBPDS) system. It was found that the partially filled C-purlin beam can significantly affect the system in the elastic and plastic ranges for the specimens (CBPDS-DF, CBPDS-DS, and CBPDS-S). The bending capacity of the specimens with varied beam configurations (CBPDS-DF, CBPDS-DS, and CBPDS-S) was decreased by about 50% when using a partially filled specimen from Le to Le/5. This happens because there is less concrete in the area that is only partially filled to help resist bending forces, which in turn will accelerate its failure.

Zitieren

APA

Al-Attar, A. A., Zand, A. W. A., Liejy, M. C., Mutalib, A. A., & Ghdhban, I. I. (2026). Performance of Partially Concrete Filled C-purlin Beam-Slab System: Numerical Investigation. NTU Journal of Engineering and Technology, 5(1), 271-279. https://doi.org/10.56286/ne4ntb77

Vancouver

Al-Attar AA, Zand AWA, Liejy MC, Mutalib AA, Ghdhban II. Performance of Partially Concrete Filled C-purlin Beam-Slab System: Numerical Investigation. NTU Journal of Engineering and Technology. 2026;5(1):271-279. doi:10.56286/ne4ntb77

BibTeX
@article{AlAttar2026,
  author = {Al-Attar, Alyaa A. and Zand, Ahmed W. Al and Liejy, Mohammed Ch. and Mutalib, Azrul A. and Ghdhban, Idan I.},
  title = {Performance of Partially Concrete Filled C-purlin Beam-Slab System: Numerical Investigation},
  journal = {NTU Journal of Engineering and Technology},
  year = {2026},
  volume = {5},
  number = {1},
  pages = {271--279},
  doi = {10.56286/ne4ntb77}
}
Kostenlos starten →