Evaluation of artifacts in cone-beam computed tomography from different intraradicular pins and cementation materials using different exposure protocols

Jhonatan Thiago Lacerda-Santos iD, Gélica Lima Granja iD, Raelly Katharinne Lima Meneses iD, Martina Gerlane de Oliveira Pinto iD, Daniela Pita de Melo iD, Jalber Almeida Dos Santos iD

Imaging Science in Dentistry · 2026 · 56 (2) · 176

DOI: 10.5624/isd.20250320 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Imaging Science in Dentistry, 2026. Verfasst von Jhonatan Thiago Lacerda-Santos und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Oral Diagnosis, State University of Paraíba, Campina Grande, Brazil. Die Arbeit nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 3.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To evaluate the generation of artifacts from intraradicular pins and cementation materials in cone-beam computed tomography images, using different exposure protocols.Materials and Methods: Sixty extracted single-rooted premolars human were divided into six groups such as G1: Fiberglass pin with Allcem cement, G2: Metal core fiberglass pin core with Allcem cement, G3: metal core fiberglass pin with Allcem Core cement, G4: Fiberglass pin with Allcem Core cement, G5: Fiberglass pin with Panavia cement, and G6: metal core fiberglass pin with Panavia cement.CBCT images were acquired on the Orthophos XG ® 3D (Sirona Dental Systems, Bensheim, Germany) following the protocols with the exposure parameters; 1) high definition (HD) mode (70 kV and 6 mA, voxel size 100 μm, scan time 14 s, 500 basis images), and 2) non-HD mode (70 kV and 10 mA, voxel size 160 μm, scan time 5 s, 200 basis images).Two-way analysis of variance (ANOVA) and Tukey HSD post-hoc tests, Fisher's exact test and the McNemar test were performed to detect statistically significant factors.

Results

For both HD and non-HD acquisition modes, the percentage of severe artifacts was higher in groups G3 and G6 (P 0.05). Conclusion:The type of fiberglass pin and cement used did not affect the production of the artifacts.When evaluating the scanning modes, the non-HD mode, which had lower mAs and fewer image bases, showed less artifact severity on the assessed CBCT scans.(Imaging Sci Dent 20250320)

Schlagwörter

Stichwörter der Autor:innen

ArtefactsCone-Beam Computed TomographyDiagnostic ImagingRoot Canal Filling Materials

Autor:innen und Institutionen

  • Department of Oral Diagnosis, State University of Paraíba, Campina Grande, Brazil.
  • Department of Dentistry, UNIFIP Campina Grande, Campina Grande, Brazil.
  • Department of Oral Radiology, Patos University Center, Patos, Brazil.
  • Department of Dentistry, University of Saskatchewan, Saskatoon, Canada.

ORCID-Profile: Jhonatan Thiago Lacerda-Santos, Gélica Lima Granja, Raelly Katharinne Lima Meneses, Martina Gerlane de Oliveira Pinto, Daniela Pita de Melo, Jalber Almeida Dos Santos

Zitieren

APA

Lacerda-Santos, J. T., Granja, G. L., Meneses, R. K. L., de Oliveira Pinto, M. G., de Melo, D. P., & Dos Santos, J. A. (2026). Evaluation of artifacts in cone-beam computed tomography from different intraradicular pins and cementation materials using different exposure protocols. Imaging Science in Dentistry, 56(2), 176. https://doi.org/10.5624/isd.20250320

Vancouver

Lacerda-Santos JT, Granja GL, Meneses RKL, de Oliveira Pinto MG, de Melo DP, Dos Santos JA. Evaluation of artifacts in cone-beam computed tomography from different intraradicular pins and cementation materials using different exposure protocols. Imaging Science in Dentistry. 2026;56(2):176. doi:10.5624/isd.20250320

BibTeX
@article{LacerdaSantos2026,
  author = {Lacerda-Santos, Jhonatan Thiago and Granja, Gélica Lima and Meneses, Raelly Katharinne Lima and de Oliveira Pinto, Martina Gerlane and de Melo, Daniela Pita and Dos Santos, Jalber Almeida},
  title = {Evaluation of artifacts in cone-beam computed tomography from different intraradicular pins and cementation materials using different exposure protocols},
  journal = {Imaging Science in Dentistry},
  year = {2026},
  volume = {56},
  number = {2},
  pages = {176},
  doi = {10.5624/isd.20250320}
}
Kostenlos starten →