ASSESSMENT THROUGH OPTICAL COHERENCE TOMOGRAPHY OF THE EFFECTS OF LIGHT CURING TECHNIQUE ON MARGINAL SEALING IN COMPOSITE RESIN RESTORATIONS
ARACÊ · 22.07.2026 · 8 (7) · e13858
DOI: 10.56238/arev8n7-097 ↗Kurz gefasst
Fachartikel in der Zeitschrift ARACÊ, online erschienen am 22.07.2026. Verfasst von Ruth Ricardo Firmino und 9 weiteren Autor:innen. Die Arbeit nennt 53 Literaturangaben.
Abstract (Originalsprache)
Introduction
Marginal sealing failure, particularly at dentin margins, remains one of the main clinical challenges in composite resin restorations. This sealing can be directly influenced by the light curing technique employed and by the distance of the light source in relation to the increment.
Objective
To evaluate, through Optical Coherence Tomography (OCT), the marginal sealing of Class V restorations made under different light-curing techniques and distances. Methodology: Twenty-five intact bovine incisors were used, in which Class V cavity preparations with margins in enamel and dentin were made. The cavities were restored (Prime & Bond 2.1 adhesive and Spectra Smart resin) and randomly distributed into 5 groups (n = 5): G1 (Conventional, 0 mm); G2 (Conventional, 2 mm); G3 (Conventional, 6 mm); G4 (Soft-Start, 0 mm); and G5 (Pulse-Delay, 0 mm). Samples were thermocycled for 250 thermal cycles and submitted to OCT reading. The two-dimensional images generated were evaluated qualitatively and quantitatively through ImageJ software regarding the presence and extent of microleakage. Data were submitted to Kappa, Fisher's Exact, and Mann-Whitney tests (α = 0.05).
Results
Absence of microleakage was found at enamel margins for all groups. In dentin, the control group (G1) showed no gaps (0%). Increased distance negatively influenced sealing, with groups G2 and G3 showing microleakage in 60% of samples, with deeper gaps in the 6 mm group (G3). Comparison between the Conventional technique at 0 mm and modulated techniques (Soft-Start and Pulse-Delay) showed no statistically significant difference.
Conclusion
Marginal sealing in dentin is impaired by the distance of the light-curing unit tip. Additionally, light modulation techniques do not confer superiority in marginal adaptation when compared to continuous light-curing technique.
Zitieren
APA
Firmino, R. R., Santos, L. R. D., Oliveira, J. R. S. D., Camarotti, A. P. D. S. L., Neto, J. A. D. S., Lima, M. S. D. S., Lima, M. E. M., Guimarães, R. P., Nascimento, A. B. L. D., & Teixeira, H. M. (2026). ASSESSMENT THROUGH OPTICAL COHERENCE TOMOGRAPHY OF THE EFFECTS OF LIGHT CURING TECHNIQUE ON MARGINAL SEALING IN COMPOSITE RESIN RESTORATIONS. ARACÊ, 8(7), e13858. https://doi.org/10.56238/arev8n7-097
Vancouver
Firmino RR, Santos LRD, Oliveira JRSD, Camarotti APDSL, Neto JADS, Lima MSDS, et al. ASSESSMENT THROUGH OPTICAL COHERENCE TOMOGRAPHY OF THE EFFECTS OF LIGHT CURING TECHNIQUE ON MARGINAL SEALING IN COMPOSITE RESIN RESTORATIONS. ARACÊ. 2026;8(7):e13858. doi:10.56238/arev8n7-097
BibTeX
@article{Firmino2026,
author = {Firmino, Ruth Ricardo and Santos, Lucas Rodrigues dos and Oliveira, José Rinaldo Santos de and Camarotti, Andressa Priscilla de Souza Leite and Neto, José Alves da Silva and Lima, Maria Sabrina dos Santos and Lima, Mirella Emerenciano Massa and Guimarães, Renata Pedrosa and Nascimento, Alexandre Batista Lopes do and Teixeira, Hilcia Mezzalira},
title = {ASSESSMENT THROUGH OPTICAL COHERENCE TOMOGRAPHY OF THE EFFECTS OF LIGHT CURING TECHNIQUE ON MARGINAL SEALING IN COMPOSITE RESIN RESTORATIONS},
journal = {ARACÊ},
year = {2026},
volume = {8},
number = {7},
pages = {e13858},
doi = {10.56238/arev8n7-097}
}
EUVIMED