Evaluasi Kinerja Perkuatan Balok T Beton Bertulang Berbasis HFRP dan CFRP Melalui Pemodelan Elemen Hingga
Journal of Infrastructure and Construction Technology · 20.11.2026 · 4 (2) · 1-20
DOI: 10.56208/jictech.4.2.1-20 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Infrastructure and Construction Technology, online erschienen am 20.11.2026. Verfasst von M. Khairi Ihsan und 1 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
External strengthening using fibre-reinforced polymer (FRP) is widely adopted to enhance the flexural capacity of reinforced concrete (RC) T-beams. However, brittle failure modes triggered by premature debonding remain a major challenge in structural modelling. This comparative review aims to evaluate and synthesise the agreement between finite element modelling (FEM) predictions and experimental results for RC T-beams strengthened with hybrid FRP (HFRP) and carbon FRP (CFRP) across varied strengthening configurations. A quantitative assessment was conducted on four parameters: ultimate load capacity (Pmax), critical deflections (δy, δmax, δu), displacement ductility (μΔ), and dissipated energy (Ed). The synthesis confirms that external FRP strengthening consistently increases experimental peak loads (for instance, from 236.0 kN to 291.0 kN), yet exerts opposing effects on peak deflection depending on the strengthening layout and bonded span length. The flexural capacity gains are generally accompanied by a 9-56% reduction in experimental ductility compared with control specimens, whereas transverse strip configurations preserve ductility more effectively and absorb 18-73% more energy (0.91-1.12 kJ) than full-width plates (0.65-0.77 kJ). Regarding numerical validation, FEM simulations predict ultimate load capacities with high accuracy against physical tests (such as 208.5 kN vs. 210.0 kN for BFR1 and 301.0 kN vs. 297.0 kN for SB2), but overestimate initial elastic stiffness, resulting in substantially smaller yield deflections (δy). Owing to the perfect-bond assumption that neglects post-peak brittle delamination, standard FEM analyses overestimate ductility indices (μFEM/μEksp reaching 1.12-2.32) and yield 4.13- 45.89% higher dissipated energy across most specimens. These findings underscore the necessity of incorporating cohesive zone modelling at the concrete-FRP interface to capture actual brittle failure accurately.
Zitieren
APA
Ihsan, M. K., & Ridwan, R. (2026). Evaluasi Kinerja Perkuatan Balok T Beton Bertulang Berbasis HFRP dan CFRP Melalui Pemodelan Elemen Hingga. Journal of Infrastructure and Construction Technology, 4(2), 1-20. https://doi.org/10.56208/jictech.4.2.1-20
Vancouver
Ihsan MK, Ridwan R. Evaluasi Kinerja Perkuatan Balok T Beton Bertulang Berbasis HFRP dan CFRP Melalui Pemodelan Elemen Hingga. Journal of Infrastructure and Construction Technology. 2026;4(2):1-20. doi:10.56208/jictech.4.2.1-20
BibTeX
@article{Ihsan2026,
author = {Ihsan, M. Khairi and Ridwan, Ridwan},
title = {Evaluasi Kinerja Perkuatan Balok T Beton Bertulang Berbasis HFRP dan CFRP Melalui Pemodelan Elemen Hingga},
journal = {Journal of Infrastructure and Construction Technology},
year = {2026},
volume = {4},
number = {2},
pages = {1--20},
doi = {10.56208/jictech.4.2.1-20}
}
EUVIMED