EUVIMEDEUVIMED entdecken
Crossref

Airway interventions during intravenous anesthesia in children undergoing direct laryngoscopy for surgical procedures using high flow versus low flow nasal oxygen. Flowkid

E Devriendt, V Saldien, S Aerts, S Maes

Acta Anaesthesiologica Belgica · 29.12.2025 · 76 (Supplement 1) · 47

DOI: 10.56126/76.s.03 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Acta Anaesthesiologica Belgica, online erschienen am 06.03.2026. Verfasst von E Devriendt und 3 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Direct laryngoscopy in pediatric patients presents anesthetic challenges, particularly in maintaining airway patency and oxygenation. High-flow nasal oxygen therapy (Optiflow™) has been proposed as an alternative to conventional low-flow oxygen, potentially improving mucosal hydration and respiratory stability.

Objectives

This study compared airway responses and anesthetic interventions when using high-flow and low- flow oxygen in children undergoing direct laryngoscopy for supraglottoplasty. The impact of humidified, heated air on postoperative mucosal quality and surgical conditions was also assessed. Design and setting: A prospective randomized controlled study conducted in the operating rooms of Antwerp University Hospital. Materials and methods: The primary endpoint was a composite endpoint, namely airway responses and/or interventions (ARIN) and consisted of the incidence of airway responses, including desaturation (SpO2 < 90% for >30 sec), bradycardia/tachycardia (≥30% change from baseline), and need for airway interventions (mask ventilation, nasopharyngeal airway, or intubation). Secondary endpoints included postoperative mucosal quality and surgeon satisfaction.

Results

ARIN occurred in 74% of patients, with no significant difference between groups (p=0.628). The number of ARIN per patient was higher in the low flow group (n=33 vs n=10), although not statistically significant (p=0.621). Sub analysis showed a slightly higher number of patients with desaturation in the low flow oxygen group (n=2 vs n=3), though total desaturation events were higher in the low-flow group (n=8 vs. n=2). Apnea occurred in 5 (55.6%) high-flow and 7 (70%) low-flow patients. Intubation was required in two (20%) low-flow patients but none in the high-flow group (p=0.167). Postprocedural mucosal quality was significantly better in high-flow patients (p

Zitieren

APA

Devriendt, E., Saldien, V., Aerts, S., & Maes, S. (2025). Airway interventions during intravenous anesthesia in children undergoing direct laryngoscopy for surgical procedures using high flow versus low flow nasal oxygen. Flowkid. Acta Anaesthesiologica Belgica, 76(Supplement 1), 47. https://doi.org/10.56126/76.s.03

Vancouver

Devriendt E, Saldien V, Aerts S, Maes S. Airway interventions during intravenous anesthesia in children undergoing direct laryngoscopy for surgical procedures using high flow versus low flow nasal oxygen. Flowkid. Acta Anaesthesiologica Belgica. 2025;76(Supplement 1):47. doi:10.56126/76.s.03

BibTeX
@article{Devriendt2025,
  author = {Devriendt, E and Saldien, V and Aerts, S and Maes, S},
  title = {Airway interventions during intravenous anesthesia in children undergoing direct laryngoscopy for surgical procedures using high flow versus low flow nasal oxygen. Flowkid},
  journal = {Acta Anaesthesiologica Belgica},
  year = {2025},
  volume = {76},
  number = {Supplement 1},
  pages = {47},
  doi = {10.56126/76.s.03}
}
Kostenlos starten →