EUVIMEDEUVIMED entdecken
Crossref

An observational study to determine whether alignment of endotracheal tube indicator line with the vocal cords results in appropriate depth of intubation

M.C. Kapoor, T Salwan, S Garg, A Puri, V Gupta

Acta Anaesthesiologica Belgica · 2020

DOI: 10.56126/71.2.5 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Acta Anaesthesiologica Belgica, 2020. Verfasst von M.C. Kapoor und 4 weiteren Autor:innen. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 23 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Inappropriate endotracheal tube placement depth may be associated with complications.

Objective

To determine whether the accurate alignment of the indicator ring on the endotracheal tube at the level of the vocal cords, results in its appropriate placement.

Design

Prospective observational study. Patients: 98 adult patients scheduled for general anesthesia with orotracheal intubation.

Interventions

The indicator band mark on the endotracheal tube was accurately placed at the vocal cords level under video-laryngoscope view. The tube length at the right upper incisor and the distance between its tip and the carina was measured using fibreoptic bronchoscope. Data to validate methods to predict insertion depth was collected and evaluated. Main Outcome: To determine the distance between the tip of the endotracheal tube and the carina.

Results

The endotracheal tube tip depth was inap- propriate in 46.94% cases and was

Zitieren

APA

Kapoor, M., Salwan, T., Garg, S., Puri, A., & Gupta, V. (2020). An observational study to determine whether alignment of endotracheal tube indicator line with the vocal cords results in appropriate depth of intubation. Acta Anaesthesiologica Belgica. https://doi.org/10.56126/71.2.5

Vancouver

Kapoor M, Salwan T, Garg S, Puri A, Gupta V. An observational study to determine whether alignment of endotracheal tube indicator line with the vocal cords results in appropriate depth of intubation. Acta Anaesthesiologica Belgica. 2020. doi:10.56126/71.2.5

BibTeX
@article{Kapoor2020,
  author = {Kapoor, M.C. and Salwan, T and Garg, S and Puri, A and Gupta, V},
  title = {An observational study to determine whether alignment of endotracheal tube indicator line with the vocal cords results in appropriate depth of intubation},
  journal = {Acta Anaesthesiologica Belgica},
  year = {2020},
  doi = {10.56126/71.2.5}
}
Kostenlos starten →