EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Detection of synthetically generated heat pump COP degradation under varying operating conditions: a comparison of a COP threshold and a Hist Gradient Boosting model

Paweł, Jan Sobczak, Antoni Ciesielski, Kamil Łodygowski

Journal of Sustainable Technologies · 23.11.2026 · 117 (2) · 47-58

DOI: 10.5604/01.3001.0055.9841 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Sustainable Technologies, erschienen am 23.11.2026. Verfasst von Paweł und 3 weiteren Autor:innen. Die Arbeit nennt 15 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Heat pump Coefficient of Performance (COP) changes naturally with operating conditions, so a single fixed COP threshold may cause an incorrect interpretation of a normal change in operating point as performance degradation. This study examines whether supervised machine learning can distinguish synthetically generated COP degradation from such normal operating changes more reliably than a fixed threshold. We used the public AI-DHC synthetic benchmark, with 100 simulations from boundary conditions bc01-bc04 for training (329,115 time-point observations) and 10 disjoint bc00 simulations for testing (40,032 observations). Ten predefined classifier configurations were compared. Hist Gradient Boosting (HGB) provided the best result among the tested configurations. Its F1 score, which balances precision and recall, was 0.895, compared with 0.601 for the training-derived COP≤1.83 threshold. Detection was easier for abrupt degradation than for progressive degradation, and the earliest stage of progressive degradation remained the most difficult to identify. Additional analyses showed that thermal and electrical power carried most of the diagnostic information, while the wider operating context improved performance further. The findings apply only to controlled synthetic data and do not demonstrate performance on real heat pump installations. They nevertheless show why a multivariable model that interprets efficiency in its operating context can be more robust than one global COP threshold when boundary conditions change.

Zitieren

APA

Paweł, Sobczak, J., Ciesielski, A., & Łodygowski, K. (2026). Detection of synthetically generated heat pump COP degradation under varying operating conditions: a comparison of a COP threshold and a Hist Gradient Boosting model. Journal of Sustainable Technologies, 117(2), 47-58. https://doi.org/10.5604/01.3001.0055.9841

Vancouver

Paweł, Sobczak J, Ciesielski A, Łodygowski K. Detection of synthetically generated heat pump COP degradation under varying operating conditions: a comparison of a COP threshold and a Hist Gradient Boosting model. Journal of Sustainable Technologies. 2026;117(2):47-58. doi:10.5604/01.3001.0055.9841

BibTeX
@article{Pawe2026,
  author = {Paweł and Sobczak, Jan and Ciesielski, Antoni and Łodygowski, Kamil},
  title = {Detection of synthetically generated heat pump COP degradation under varying operating conditions: a comparison of a COP threshold and a Hist Gradient Boosting model},
  journal = {Journal of Sustainable Technologies},
  year = {2026},
  volume = {117},
  number = {2},
  pages = {47--58},
  doi = {10.5604/01.3001.0055.9841}
}
Kostenlos starten →