Multi-response optimization of electropolishing parameters for titanium microfluidic channel sidewalls using Taguchi-Grey relational analysis
Archives of Materials Science and Engineering · 01.07.2026
DOI: 10.5604/01.3001.0055.9830 ↗Kurz gefasst
Fachartikel in der Zeitschrift Archives of Materials Science and Engineering, erschienen am 01.07.2026. Verfasst von M.A. Setyawan und 3 weiteren Autor:innen.
Abstract (Originalsprache)
To determine the optimal electropolishing parameters (ethanol concentration in NaCl ethylene glycol electrolyte, applied voltage, and machining gap) for commercially pure titanium microfluidic channels, aiming to minimize undercut (lateral material removal beneath a mask) while also achieving a high material removal rate (MRR). The study addresses the gap in existing research that focuses mainly on surface roughness and MRR, overlooking undercut as a critical criterion for dimensional accuracy in precision biomedical devices.
A Taguchi L₉ orthogonal array was used to design the experiments with three parameters each at three levels. The smaller the better signal to noise (S/N) ratio was applied for undercut minimization, and the larger the better S/N ratio for MRR maximization. Pareto analysis of variance (ANOVA) was employed to determine the contribution percentage of each parameter and identify the most significant factors. To address the trade off between the two conflicting responses, Grey Relational Analysis (GRA) was subsequently performed to provide a unified multi response optimization framework. Verification experiments were conducted under the predicted optimal conditions to validate the Taguchi results.
The optimal combination for minimum undercut (0.021 mm) is 15 vol.% ethanol, 15 V, and 10 mm machining gap. For high MRR (0.280 mg/s), the optimum is 25 vol.% ethanol, 25 V, and 10 mm gap. Ethanol concentration is identified as the most influential factor, with approximate contribution ratios of 49% for undercut and 56% for MRR, followed by applied voltage (45% and 35%, respectively), while machining gap has a negligible effect (5% and 9%). The GRA results identified the optimal compromise condition for balanced performance as A2B3C2 (20 V, 25 vol.%, 20 mm) , with ethanol concentration being the most influential factor for multi response performance (range = 0.1032). Verification experiments confirmed the validity and reproducibility of the optimized parameters, with deviations below 10% for the primary responses—4.8% for undercut under A1B1C1 and 7.8% for MRR under A3B3C1.
The study was conducted on commercially pure titanium with a specific microfluidic channel geometry; results may vary for other alloys or more complex 3D structures. The electropolishing time was fixed at 5 minutes based on previous work, while other variables such as temperature, stirring intensity, and electrolyte aging were held constant to isolate the primary parameters. Therefore, the optimal conditions identified here should be considered as such within the investigated design space. Future studies incorporating temperature, hydrodynamic effects, and cathode geometry are recommended to determine a more comprehensive global optimum.
The mechanistic interpretation of the ethanol effect, concerning the TiCl₄ viscous layer and ethanol barrier, is primarily based on well established experimental evidence from prior studies on titanium electropolishing in NaCl ethylene glycol ethanol electrolytes, rather than on direct in situ measurements conducted in this work. While direct measurements of film thickness, viscosity profiles, and local current distribution were not performed here, the observed trends in MRR and undercut are highly consistent with these previously proven physicochemical effects. Such quantitative characterizations are recommended for future mechanistic investigations.
Additionally, further investigation should examine the interplay between undercut and surface roughness under the same conditions and test the optimized parameters on fully assembled implantable kidney devices.
Manufacturers of precision biomedical components (e.g., microfluidic channels for artificial kidney dialyzers) can directly apply the two optimal parameter sets: one for preserving intricate channel geometry (low undercut) and another for high throughput polishing where slight undercut is tolerable. The finding that machining gap (10-30 mm) is insignificant simplifies experimental setup and reduces precision requirements for electrode positioning, lowering production costs. The GRA results further provide a compromise condition (A2B3C2: 20 V, 25 vol.%, 20 mm) for applications requiring a balance between accuracy and productivity.
While undercut is a recognized phenomenon in electrochemical micromachining, its systematic optimization in the electropolishing of commercially pure titanium microfluidic channels, particularly for implantable biomedical devices, has not been previously reported. This study provides the first comprehensive parametric optimization of undercut alongside MRR for this specific material process combination, using Taguchi based Pareto ANOVA complemented by Grey Relational Analysis for multi response optimization. The quantitative contribution ratios and the multi response compromise framework established here offer a practical guideline for parameter selection in precision manufacturing of titanium micro components.
Zitieren
APA
Setyawan, M., Prihandana, G., Sriani, T., & Mahardika, M. (2026). Multi-response optimization of electropolishing parameters for titanium microfluidic channel sidewalls using Taguchi-Grey relational analysis. Archives of Materials Science and Engineering. https://doi.org/10.5604/01.3001.0055.9830
Vancouver
Setyawan M, Prihandana G, Sriani T, Mahardika M. Multi-response optimization of electropolishing parameters for titanium microfluidic channel sidewalls using Taguchi-Grey relational analysis. Archives of Materials Science and Engineering. 2026. doi:10.5604/01.3001.0055.9830
BibTeX
@article{Setyawan2026,
author = {Setyawan, M.A. and Prihandana, G.S. and Sriani, T. and Mahardika, M.},
title = {Multi-response optimization of electropolishing parameters for titanium microfluidic channel sidewalls using Taguchi-Grey relational analysis},
journal = {Archives of Materials Science and Engineering},
year = {2026},
doi = {10.5604/01.3001.0055.9830}
}
EUVIMED