Detection efficiency of two- and three-gamma positronium annihilations in the Total-Body J-PET detector
Bio-Algorithms and Med-Systems · 31.10.2026 · 22 (2 - Advances in Medical Imaging,) · 1-9
DOI: 10.5604/01.3001.0055.9712 ↗Kurz gefasst
Fachartikel in der Zeitschrift Bio-Algorithms and Med-Systems, erschienen am 31.10.2026. Verfasst von Kamila Kasperska und 2 weiteren Autor:innen. Die Arbeit nennt 56 Literaturangaben.
Abstract (Originalsprache)
Objective
We aimed to investigate the detection efficiency of two-gamma (2γ) and three-gamma (3γ) positronium annihilation events in the Total-Body J-PET (TB J-PET) detector and the influence of the energy-deposition threshold and annihilation position on the registration efficiency.
Materials: A realistic human body XCAT phantom was used to model the spatial distribution of positronium annihilations within the human body. The phantom was implemented in the simulated TB J-PET geometry.
Methods
Monte Carlo (MC) simulations were performed using GATE version 9.4.1 with the TB J-PET detector geometry. Para-positronium (p-Ps) and ortho-positronium (o-Ps) decays were simulated to represent 2γ and 3γ annihilation events, respectively. The detection efficiency was evaluated for energy-deposition thresholds of 0, 30 and 50 keV. Registered events were identified from the simulated photon interaction history and analysed according to their true point of origin within the phantom.
Results
The detection efficiency depended on the applied energy-deposition threshold and the point of origin within the phantom. The influence of the energy-deposition threshold differed between the 2γ and 3γ annihilation channels, resulting in changes in their registration efficiencies from 4.7% to 3.3% and from 1.11% to 0.22%, respectively, with efficiency ratios between the channels changing from 4.2 to 15.
Discussion
The different energy distributions of photons emitted in 2γ and 3γ decays led to different changes in detection efficiency with an increasing energy-deposition threshold. These differences should be considered when determining the 3γ/2γ annihilation rate ratio.
Conclusions
The results characterise the detection efficiency of 2γ and 3γ positronium annihilations in the TB J-PET geometry and aid the further development of quantitative 3γ/2γ imaging methods.
Zitieren
APA
Kasperska, K., Skurzok, M., & Moskal, P. (2026). Detection efficiency of two- and three-gamma positronium annihilations in the Total-Body J-PET detector. Bio-Algorithms and Med-Systems, 22(2 - Advances in Medical Imaging,), 1-9. https://doi.org/10.5604/01.3001.0055.9712
Vancouver
Kasperska K, Skurzok M, Moskal P. Detection efficiency of two- and three-gamma positronium annihilations in the Total-Body J-PET detector. Bio-Algorithms and Med-Systems. 2026;22(2 - Advances in Medical Imaging,):1-9. doi:10.5604/01.3001.0055.9712
BibTeX
@article{Kasperska2026,
author = {Kasperska, Kamila and Skurzok, Magdalena and Moskal, Paweł},
title = {Detection efficiency of two- and three-gamma positronium annihilations in the Total-Body J-PET detector},
journal = {Bio-Algorithms and Med-Systems},
year = {2026},
volume = {22},
number = {2 - Advances in Medical Imaging,},
pages = {1--9},
doi = {10.5604/01.3001.0055.9712}
}