EUVIMEDEUVIMED entdecken
Crossref

TRANSFORMATION OF A WAREHOUSE BUILDING TOWARDS ANNUAL NET-ZERO ELECTRICITY PERFORMANCE: ENERGY, ENVIRONMENTAL AND TECHNO-ECONOMIC ANALYSIS OF A LOGISTICS FACILITY

Maciej Knapik

Zeszyty Naukowe SGSP · 29.06.2026 · 1 (98) · 41-62

DOI: 10.5604/01.3001.0055.8183 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Zeszyty Naukowe SGSP, erschienen am 29.06.2026. Verfasst von Maciej Knapik. Die Arbeit nennt 30 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The decarbonization of warehouse and logistics buildings is becoming an important component of climate policy and energy security. This paper evaluates the potential for transforming a representative warehouse building towards annual net-zero electricity performance through the combined application of energy efficiency measures, rooftop photovoltaics and a battery-supported sensitivity scenario. The study is based on a model logistics facility with a floor area of 10000 [m] and includes an annual electricity balance, a simplified temporal interpretation of demand–generation mismatch, an operational carbon assessment and a techno-economic evaluation. The model represents a warehouse facility located in a Central European climatic context, and the operational carbon assessment uses a grid emission factor of 0.40 kg [CO₂/kWh]. The modernisation package comprises LED lighting, intelligent lighting control, HVAC optimisation, destratification, compressed air system improvement and a rooftop photovoltaic system. In addition, a simplified battery-supported scenario was analysed in order to assess the effect of storage on self-consumption and grid imports. The results indicate that annual electricity demand can be reduced from 1200 to approximately 800 [MWh/year]. A rooftop PV system with a capacity of about 1.04 [MWp] can generate approximately 1040 [MWh/year], which allows the building to achieve annual net-zero electricity performance in the reference case. In the no-storage scenario, direct on-site PV utilisation reaches 750 [MWh/year], while in the battery-supported scenario, the annual battery-supported PV supply to the load increases and residual grid imports are eliminated in the simplified model. The efficiency package reduces operational carbon emissions by about 160 [t CO₂/year]. The techno-economic indicators reported in the paper pertain to the efficiency-plus-PV package without battery storage and remain favourable under the adopted assumptions, with a simple payback period of less than 4 years. The study confirms that warehouse buildings can significantly improve their operational energy performance and, under favourable technical conditions, become active elements of distributed energy systems. The efficiency-plus-PV package yields an indicative NPV of approximately 1.8 million EUR and an IRR of approximately 24% under the adopted assumption.

Zitieren

APA

Knapik, M. (2026). TRANSFORMATION OF A WAREHOUSE BUILDING TOWARDS ANNUAL NET-ZERO ELECTRICITY PERFORMANCE: ENERGY, ENVIRONMENTAL AND TECHNO-ECONOMIC ANALYSIS OF A LOGISTICS FACILITY. Zeszyty Naukowe SGSP, 1(98), 41-62. https://doi.org/10.5604/01.3001.0055.8183

Vancouver

Knapik M. TRANSFORMATION OF A WAREHOUSE BUILDING TOWARDS ANNUAL NET-ZERO ELECTRICITY PERFORMANCE: ENERGY, ENVIRONMENTAL AND TECHNO-ECONOMIC ANALYSIS OF A LOGISTICS FACILITY. Zeszyty Naukowe SGSP. 2026;1(98):41-62. doi:10.5604/01.3001.0055.8183

BibTeX
@article{Knapik2026,
  author = {Knapik, Maciej},
  title = {TRANSFORMATION OF A WAREHOUSE BUILDING TOWARDS ANNUAL NET-ZERO ELECTRICITY PERFORMANCE: ENERGY, ENVIRONMENTAL AND TECHNO-ECONOMIC ANALYSIS OF A LOGISTICS FACILITY},
  journal = {Zeszyty Naukowe SGSP},
  year = {2026},
  volume = {1},
  number = {98},
  pages = {41--62},
  doi = {10.5604/01.3001.0055.8183}
}
Kostenlos starten →