Quantum Entanglement Degree, Mean Positronium Lifetime, and the 3γ/2γ Annihilation-Rate Ratio as Novel PET Biomarkers for Hypoxia – Concept, Challenges, and Predictions
Bio-Algorithms and Med-Systems · 31.05.2026 · 22 (1) · 56-77
DOI: 10.5604/01.3001.0055.7461 ↗Kurz gefasst
Fachartikel in der Zeitschrift Bio-Algorithms and Med-Systems, erschienen am 31.05.2026. Verfasst von Paweł Moskal. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 133 Literaturangaben.
Abstract (Originalsprache)
Objective
Hypoxia is a critical factor in tumour aggressiveness, metastasis, and treatment resistance. Despite its clinical significance, a non-invasive, high-precision method for assessing and mapping tissue oxygenation in vivo remains a major challenge in medicine.This study explores the potential of positronium imaging and quantum entanglement (QE) imaging as next-generation biomarkers for hypoxia. This manuscript introduces a novel method to assess tissue oxygen concentration via the QE of photons originating from positronium – a bound state of an electron and a positron – which is produced within the patient’s body during positron emission tomography (PET). We also investigate the possibility of assessing hypoxia by simultaneously detecting positronium lifetime and the positronium decay rate ratio.
Methods
We introduce two distinct quantum sensing approaches.
Method
1 utilises the correlation between oxygen concentration and ortho-positronium (o-Ps) decay rates, relying on the simultaneous measurement of the mean o-Ps lifetime (τoPs) and the 3γ-to-2γ annihilation rate ratio of o-Ps (RoPs-3γ/2γ).
Method
2 introduces a novel hypothesis based on the degree of QE of annihilation photons. This method leverages recent discoveries indicating that the degree of QE is sensitive to the relative contribution of annihilation mechanisms (pick-off vs. conversion), which in turn depends on the oxygen concentration. We estimate the rate of conversion processes as a function of the partial pressure of oxygen (pO2) in water, isopropanol, cyclohexane, isooctane, and adipose tissue. We consider dependence of RoPs-3γ/2γ and τoPs, as well as the degree of QE, on oxygen pressure in the studied substances. Finally, we derive a formula for pO2 as a function of RoPs-3γ/2γ and τoPs and estimate the measurement accuracy required for these parameters – and for the degree of QE – to sense in-vivo oxygen pressure in the range between hypoxic and physoxic conditions.
Results
Theoretical models and quantitative estimates for RoPs-3γ/2γ, τoPs and for the degree of QE (CQE and RQE) as a function of pO2 are provided for water, organic solvents (isopropanol, cyclohexane, isooctane), and adipose tissue. Applying the formulas derived under the working hypothesis that in pick-off process the photons are not entangled, we estimated that for pO2 = 0, the degree of QE CQE is equal to 0.890 for adipose, 0.886 for isopropanol, 0.867 for water, 0.818 for cyclohexane, and 0.784 for isooctane. These results indicate that distinguishing between various tissue types requires a precision of σ(CQE) ≈ 0.01. We also estimated the values of τoPs, RoPs-3γ/2γ, and R3γ/2γ, as well as the changes in τoPs, RoPs-3γ/2γ and CQE between physoxic (pO2 ≈ 50 mmHg) and hypoxic (pO2 = 10 mmHg) conditions amount to ΔτoPs = 5 ps (water), 48 ps (adipose), 182 ps (isopropanol), 187 ps (cyclohexane), 444 ps (isooctane), ΔRoPs-3γ/2γ = 0.000045 (water), 0.0004 (adipose), 0.0015 (isopropanol), 0.0015 (cyclohexane), 0.0036 (isooctane), and ΔCQE = 0.0003 (water), 0.0019 (adipose), 0.0054 (isopropanol), 0.0106 (cyclohexane), 0.0243 (isooctane). To distinguish between physoxic and hypoxic conditions in vivo, the measurement precision σ(τoPs), σ(RoPs-3γ/2γ) and σ(CQE) must be several times higher than the predicted changes in these values.
Conclusions
This work establishes a theoretical and methodological foundation for using the QE of photons and the properties of positronium as transformative diagnostic tools for the non-invasive assessment and mapping of tissue oxygenation in the human body. It demonstrates that QE can serve not only as a tool for improving PET image quality through noise reduction, but also as a completely new category of biomarker. Quantitative estimations of the effect of oxygen pressure on positronium parameters, as well as the event statistics required for hypoxia assessment, are feasible using the multi-photon total-body J-PET scanner based on plastic scintillators. Furthermore, such assessments will be possible with next-generation, high-sensitivity crystal-based PET scanners, provided they are upgraded to support multi-photon signal acquisition for τoPs and 3γ-to-2γ imaging, and double Compton scattering for imaging CQE – the degree of QE.
Zitieren
APA
Moskal, P. (2026). Quantum Entanglement Degree, Mean Positronium Lifetime, and the 3γ/2γ Annihilation-Rate Ratio as Novel PET Biomarkers for Hypoxia – Concept, Challenges, and Predictions. Bio-Algorithms and Med-Systems, 22(1), 56-77. https://doi.org/10.5604/01.3001.0055.7461
Vancouver
Moskal P. Quantum Entanglement Degree, Mean Positronium Lifetime, and the 3γ/2γ Annihilation-Rate Ratio as Novel PET Biomarkers for Hypoxia – Concept, Challenges, and Predictions. Bio-Algorithms and Med-Systems. 2026;22(1):56-77. doi:10.5604/01.3001.0055.7461
BibTeX
@article{Moskal2026,
author = {Moskal, Paweł},
title = {Quantum Entanglement Degree, Mean Positronium Lifetime, and the 3γ/2γ Annihilation-Rate Ratio as Novel PET Biomarkers for Hypoxia – Concept, Challenges, and Predictions},
journal = {Bio-Algorithms and Med-Systems},
year = {2026},
volume = {22},
number = {1},
pages = {56--77},
doi = {10.5604/01.3001.0055.7461}
}
EUVIMED