Pacemaker implantation via occluded superior vena cava
In a Good Rhythm · 2017
DOI: 10.5604/01.3001.0010.7494 ↗Kurz gefasst
Fachartikel in der Zeitschrift In a Good Rhythm, 2017. Verfasst von Aleksander Maciąg. Die Arbeit nennt 2 Literaturangaben.
Abstract (Originalsprache)
The author describes the case of the superior vena cava occlusion detected during the new implantation of thepacemaker after lead extraction due to pocket infection. New electrode was implanted via the right subclavianvein. The occlusion in the superior vena cava was overcome with a guidewire (0.32 F) and a diagnostic catheter(JR2).
Zitieren
APA
Maciąg, A. (2017). Pacemaker implantation via occluded superior vena cava. In a Good Rhythm. https://doi.org/10.5604/01.3001.0010.7494
Vancouver
Maciąg A. Pacemaker implantation via occluded superior vena cava. In a Good Rhythm. 2017. doi:10.5604/01.3001.0010.7494
BibTeX
@article{Macig2017,
author = {Maciąg, Aleksander},
title = {Pacemaker implantation via occluded superior vena cava},
journal = {In a Good Rhythm},
year = {2017},
doi = {10.5604/01.3001.0010.7494}
}