THE APTUS™ HELI-FX™ ENDOANCHOR™ SYSTEM – THE INNOVATIVE ENDOVASCULAR REPAIR METHOD FOR THE PATIENT WITH POSTEVAR TYPE IA ENDOLEAK
Acta Neuropsychologica · 2017
DOI: 10.5604/01.3001.0010.2408 ↗Kurz gefasst
Fachartikel in der Zeitschrift Acta Neuropsychologica, 2017. Verfasst von Tomasz Muszyński und 5 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref).
Abstract (Originalsprache)
[b]Background:[/b] The aim of our study was to present an innovative endovascular technique – the Aptus™ Heli-FX™ EndoAnchor™ system com bined with the Endurant Stent Graft cuff used as a method of choice for the patient in a very poor general condition with symptomatic abdominal aneurysm and a post-EVAR type IA endoleak.[b]Case study: [/b]An 85-year-old male patient, was operated on in March 2016 with endovascular aneurysm repair (EVAR) of a 9.3 cm in diameter ruptured abdominal aneurysm (RAA), accompanied by disturbance to the coagulation profile (prolonged INR of 3.3 because of anticoagulant treatment with Rivaroxaban due to atrial fibrillation). 9 months later, he developed a severe abdominal pain and was urgently referred to the Vascular Surgery Department, at the John Paul II Hospital, Kraków. The Angio-CT xamination revealed the type IA and II endoleaks and a recurrence of the rupture symptoms. He was successfully operated on using an innovative endovascular repair system, the Aptus™ Heli-FX™ ndoAnchor™ system with a combination of other endovascular procedures, such as Endurant Stent Graft cuff implantation. [b]Conclusions:[/b]The innovative endovascular repair system, Aptus™ Heli-FX™ EndoAnchor™ together with the Endurant Stent Graft cuff was successfully used in the treatment of the patient. This technique prevented him from developing serious complications or even death and gave him a much better quality of life in comparison with open surgery repair.
Zitieren
APA
Muszyński, T., Polak, K., Krzywoń, J., Zbierska-Rubinkiewicz, K., Kwiatkowski, T., & Trystuła, M. (2017). THE APTUS™ HELI-FX™ ENDOANCHOR™ SYSTEM – THE INNOVATIVE ENDOVASCULAR REPAIR METHOD FOR THE PATIENT WITH POSTEVAR TYPE IA ENDOLEAK. Acta Neuropsychologica. https://doi.org/10.5604/01.3001.0010.2408
Vancouver
Muszyński T, Polak K, Krzywoń J, Zbierska-Rubinkiewicz K, Kwiatkowski T, Trystuła M. THE APTUS™ HELI-FX™ ENDOANCHOR™ SYSTEM – THE INNOVATIVE ENDOVASCULAR REPAIR METHOD FOR THE PATIENT WITH POSTEVAR TYPE IA ENDOLEAK. Acta Neuropsychologica. 2017. doi:10.5604/01.3001.0010.2408
BibTeX
@article{Muszynski2017,
author = {Muszyński, Tomasz and Polak, Karina and Krzywoń, Julia and Zbierska-Rubinkiewicz, Katarzyna and Kwiatkowski, Tomasz and Trystuła, Mariusz},
title = {THE APTUS™ HELI-FX™ ENDOANCHOR™ SYSTEM – THE INNOVATIVE ENDOVASCULAR REPAIR METHOD FOR THE PATIENT WITH POSTEVAR TYPE IA ENDOLEAK},
journal = {Acta Neuropsychologica},
year = {2017},
doi = {10.5604/01.3001.0010.2408}
}
EUVIMED