Thrombus burden management during primary coronary bifurcation intervention: a new experimental bench model
Cardiology Journal · 2024
DOI: 10.5603/cj.a2023.0015 ↗Kurz gefasst
Fachartikel in der Zeitschrift Cardiology Journal, 2024. Verfasst von Ahmad Hayek und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Interventional Cardiology, Cardiovascular Hospital and Claude Bernard University and INSERM Unit 1060 CARMEN, Lyon, France. Hauptthemen laut MEDLINE: Percutaneous Coronary Intervention, Thrombosis, Coronary Artery Disease, Alkanesulfonic Acids. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Background
Management of thrombus burden during primary percutaneous coronary intervention (pPCI) is a key-point, given the high risk of stent malapposition and/or thrombus embolization. These issues are especially important if pPCI involves a coronary bifurcation. Herein, a new experimental bifurcation bench model to analyze thrombus burden behavior was developed.
Methods
On a fractal left main bifurcation bench model, we generated standardized thrombus with human blood and tissue factor. Three provisional pPCI strategies were compared (n = 10/group): 1) balloon-expandable stent (BES), 2) BES completed by proximal optimizing technique (POT), and 3) nitinol self-apposing stent (SAS). The embolized distal thrombus after stent implantation was weighed. Stent apposition and thrombus trapped by the stent were quantified on 2D-OCT. To analyze final stent apposition, a new OCT acquisition was performed after pharmacological thrombolysis.
Results
Trapped thrombus was significantly greater with isolated BES than SAS or BES+POT (18.8 ± 5.8% vs. 10.3 ± 3.3% and 6.2 ± 2.1%, respectively; p < 0.05), and greater with SAS than BES+POT (p < 0.05). Isolated BES and SAS tended show less embolized thrombus than BES+POT (5.93 ± 4.32 mg and 5.05 ± 4.56 mg vs. 7.01 ± 4.32 mg, respectively; p = NS). Conversely, SAS and BES+POT ensured perfect final global apposition (0.4 ± 0.6% and 1.3 ± 1.3%, respectively, p = NS) compared to isolated BES (74.0 ± 7.6%, p < 0.05).
Conclusions
This first experimental bench model of pPCI in a bifurcation quantified thrombus trapping and embolization. BES provided the best thrombus trapping, while SAS and BES+POT achieved better final stent apposition. These factors should be taken into account in selecting revascularization strategy.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Interventional Cardiology, Cardiovascular Hospital and Claude Bernard University and INSERM Unit 1060 CARMEN, Lyon, France.
- Unité d'Hémostase Clinique, Hôpital Cardiologique Louis Pradel, CRTH de Lyon, CHU de Lyon, France.
- GCS ES Axium Rambot, Aix-en-Provence, France.
- Department of Interventional Cardiology, Cardiovascular Hospital and Claude Bernard University and INSERM Unit 1060 CARMEN, Lyon, France. francois.derimay@chu-lyon.fr.
ORCID-Profile: François Dérimay
Zitieren
APA
Hayek, A., Dargaud, Y., Maillard, L., Finet, G., Bochaton, T., Rioufol, G., & Dérimay, F. (2024). Thrombus burden management during primary coronary bifurcation intervention: a new experimental bench model. Cardiology Journal. https://doi.org/10.5603/cj.a2023.0015
Vancouver
Hayek A, Dargaud Y, Maillard L, Finet G, Bochaton T, Rioufol G, et al. Thrombus burden management during primary coronary bifurcation intervention: a new experimental bench model. Cardiology Journal. 2024. doi:10.5603/cj.a2023.0015
BibTeX
@article{Hayek2024,
author = {Hayek, Ahmad and Dargaud, Yassim and Maillard, Luc and Finet, Gerard and Bochaton, Thomas and Rioufol, Gilles and Dérimay, François},
title = {Thrombus burden management during primary coronary bifurcation intervention: a new experimental bench model},
journal = {Cardiology Journal},
year = {2024},
doi = {10.5603/cj.a2023.0015}
}
EUVIMED