Transcatheter aortic valve-in-valve implantation for failed surgical aortic bioprostheses using the Navitor platform: early outcomes in a consecutive single-center cohort
Cardiology Journal · 2026
DOI: 10.5603/cj.111703 ↗Kurz gefasst
Fachartikel in der Zeitschrift Cardiology Journal, 2026. Verfasst von Robert Sobczyński und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiac Surgery and Transplantation, St. John Paul II Hospital, Krakow, Poland. sobczynski@poczta.fm. Hauptthemen laut MEDLINE: Bioprosthesis, Heart Valve Prosthesis, Aortic Valve, Transcatheter Aortic Valve Replacement. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Introduction
Transcatheter heart valve implantation into a failed surgical heart valve (THV-in-SHV) is an established reintervention strategy for degenerated aortic bioprostheses; however, early procedural outcomes, discharge hemodynamics, and standardized safety remain clinically relevant in routine practice. Material and methods. We retrospectively analyzed consecutive patients who underwent aortic THV-in-SHV with the Navitor platform between 2022 and 2025. The primary endpoint was the mean aortic gradient at discharge. Secondary endpoints included peak gradient, maximum transvalvular velocity (Vmax), paravalvular leak (PVL), Valve Academic Research Consortium-3 (VARC-3) early safety, and time from surgical aortic valve replacement (SAVR) to reintervention according to leaflet mounting.
Results
Thirty patients were included (age, 72.5 ± 9.2 years; 73.3% male). At discharge, the mean and peak aortic gradients were 16.8 ± 6.7 mmHg and 30.0 ± 11.7 mmHg, respectively. Paravalvular leak was absent, trace, or mild in 96.7%, with no severe PVL. Early safety according to VARC-3 was achieved in 86.7%. Mortality and stroke occurred in 3.3% each, and bleeding type ≥ 2 occurred in 6.7%. No acute kidney injury (AKI) stage 3, renal replacement therapy (RRT), major vascular complications, device-related intervention, or new permanent pacemaker implantation occurred. Smaller surgical valves were associated with higher residual gradients, whereas outside-mounted bioprostheses showed a shorter time to reintervention than inside-mounted designs.
Conclusions
Aortic THV-in-SHV with the Navitor platform was associated with acceptable discharge hemodynamics, low rates of clinically relevant PVL, and favorable early safety according to VARC-3. Residual gradients were driven primarily by surgical valve size despite the intra-annular design.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiac Surgery and Transplantation, St. John Paul II Hospital, Krakow, Poland. sobczynski@poczta.fm.
- Department of Interventional Cardiology, St. John Paul II Hospital, Krakow, Poland.
- Department of Interventional Cardiology, Institute of Cardiology, Jagiellonian University Medical College, St. John Paul II Hospital, Krakow, Poland.
- Department of Cardiac Surgery and Transplantation, St. John Paul II Hospital, Krakow, Poland.
- Department of Cardiac Surgery and Transplantation, Jagiellonian University Medical College, Institute of Cardiology, St. John Paul II Hospital, Krakow, Poland.
- Gabriel Narutowicz Municipal Specialist Hospital, Krakow, Poland.
ORCID-Profile: Janusz Konstanty-Kalandyk
Zitieren
APA
Sobczyński, R., Trębacz, J., Kleczyński, P., Kapelak, B., Stąpór, M., Dudkowski, F., Konstanty-Kalandyk, J., & Legutko, J. (2026). Transcatheter aortic valve-in-valve implantation for failed surgical aortic bioprostheses using the Navitor platform: early outcomes in a consecutive single-center cohort. Cardiology Journal. https://doi.org/10.5603/cj.111703
Vancouver
Sobczyński R, Trębacz J, Kleczyński P, Kapelak B, Stąpór M, Dudkowski F, et al. Transcatheter aortic valve-in-valve implantation for failed surgical aortic bioprostheses using the Navitor platform: early outcomes in a consecutive single-center cohort. Cardiology Journal. 2026. doi:10.5603/cj.111703
BibTeX
@article{Sobczyski2026,
author = {Sobczyński, Robert and Trębacz, Jarosław and Kleczyński, Paweł and Kapelak, Bogusław and Stąpór, Maciej and Dudkowski, Filip and Konstanty-Kalandyk, Janusz and Legutko, Jacek},
title = {Transcatheter aortic valve-in-valve implantation for failed surgical aortic bioprostheses using the Navitor platform: early outcomes in a consecutive single-center cohort},
journal = {Cardiology Journal},
year = {2026},
doi = {10.5603/cj.111703}
}