EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

The Utility of HACOR Score in Predicting Failure of High-Flow Nasal Oxygen in Acute Hypoxemic Respiratory Failure

Doaa M Magdy, Ahmed Metwally

Advances in Respiratory Medicine · 28.02.2021 · 89 (1) · 23-29

DOI: 10.5603/arm.a2021.0031 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Advances in Respiratory Medicine, online erschienen am 28.02.2021. Verfasst von Doaa M Magdy und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chest Diseases, Faculty of Medicine, Assuit University, Egypt. doaamagdy_2020@yahoo.com. Die Arbeit wurde bisher 23-mal zitiert (Crossref). Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

To assess the diagnostic performance of HACOR scoring system using bedside variables and to predict failure of HFNO in patients with acute hypoxemic respiratory failure (AHRF). Material and methods: 150 patients with AHRF who were receiving HFNO were enrolled in this study; to predict HFNO treatment failure. A scoring scale (HACOR score) consisted of Heart rate (beats/minute), acidosis (assessed by pH), consciousness (assessed by Glasgow coma score), oxygenation, and respiratory rate. Failure was defined as the need for intubation or death.

Results

Patients were analyzed according to the success or failure of HFNO. Total 150 patients, of which 100 (66.7%) had a successful treatment while 50 (33.3%) failed with such intervention. There was an improvement in HR and RR, and PaO₂/FiO₂ within the first hour (T1) in the success group and these parameters continued to improve even after 24 hours (T2) of HFNO treatment. Patients with HFNO failure had a higher HACOR score at initiation and after 1, 12, 24 and 48 hours. Before intubation, the highest value of the HACOR score was reached in the failure group. At 1h of HFNO assessment, the area under the receiver operating characteristic curve was 0.86, showing good predictive power for failure. We found that HACOR score at a cutoff point > 6 had 81.2% sensitivity and 91% specificity, 92.5% positive predictive value, and 71.4% negative predictive value with a diagnostic accuracy was 85%. Furthermore, the overall diagnostic accuracy exceeded 87% when the HACOR score was assessed at 1, 12, 24 or 48 h of HFNO.

Conclusions

The HACOR scale is a clinically useful bedside tool for the prediction of HFNO failure in hypoxemic patients. A HACOR score < 6 after 1 hour of HFNO highlights patients with < 85% risk of failure.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

AdultFemaleHumansMaleMiddle AgedNoninvasive VentilationOxygenOxygen Inhalation TherapyRespiratory InsufficiencyTime FactorsVital Signs

Stichwörter der Autor:innen

critical carehypoxemic respiratory failure

Substanzen

Oxygen

Autor:innen und Institutionen

  • Department of Chest Diseases, Faculty of Medicine, Assuit University, Egypt. doaamagdy_2020@yahoo.com.
  • Department of Chest Diseases, Faculty of Medicine, Assuit University, Egypt.

Zitieren

APA

Magdy, D. M., & Metwally, A. (2021). The Utility of HACOR Score in Predicting Failure of High-Flow Nasal Oxygen in Acute Hypoxemic Respiratory Failure. Advances in Respiratory Medicine, 89(1), 23-29. https://doi.org/10.5603/arm.a2021.0031

Vancouver

Magdy DM, Metwally A. The Utility of HACOR Score in Predicting Failure of High-Flow Nasal Oxygen in Acute Hypoxemic Respiratory Failure. Advances in Respiratory Medicine. 2021;89(1):23-29. doi:10.5603/arm.a2021.0031

BibTeX
@article{Magdy2021,
  author = {Magdy, Doaa M and Metwally, Ahmed},
  title = {The Utility of HACOR Score in Predicting Failure of High-Flow Nasal Oxygen in Acute Hypoxemic Respiratory Failure},
  journal = {Advances in Respiratory Medicine},
  year = {2021},
  volume = {89},
  number = {1},
  pages = {23--29},
  doi = {10.5603/arm.a2021.0031}
}