EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Poly(asparagine)-modified duplex stainless steel composite carbon paste electrode for selective electrochemical detection of dopamine

Shashanka Rajendrachari, Hareesha Nagarajappa, Varun Donnakatte Neelalochana, Rakshitha Gattavadipura Shivaraju, Ersin Demir, Santhy Antherjanam, Kazim Erden Karaoglanli

Journal of Electrochemical Science and Engineering · 23.02.2026 · 16

DOI: 10.5599/jese.3157 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Electrochemical Science and Engineering, online erschienen am 23.02.2026. Verfasst von Shashanka Rajendrachari und 6 weiteren Autor:innen. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 48 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Dopamine (DA) is a vital neurotransmitter used in clinical diagnostics and neurochemical studies. In this article, a robust, accurate, and highly sensitive method for determining DA using a duplex stainless steel (DSS)-modified carbon paste electrode (MCPE) and cyclic voltammetry is reported. To improve the sensitivity of the DSS-MCPE, the electrode was polymerized via 10 potential cycles using asparagine, a non-essential amino acid, thereby forming poly(asparagine) on the electrode surface. This polymerized electrode surface acts as a selective barrier to DA and enables the DSS-MCPE to detect DA accurately, even in the presence of interfering molecules such as ascorbic and uric acids, which have overlapping oxidation potentials. Compared with the bare carbon paste electrode (BCPE) and DSS-MCPE, poly(asp)-DSS-MCPE exhibits excellent electrochemical behaviour, a higher oxidation peak current, and improved electron transfer kinetics. The effects of variations in scan rate, pH, and DA concentration on the electrocatalytic behaviour of poly(asp)-DSS-MCPE were investigated. Also, the electrode active surface area was calculated, and the limit of detection, limit of quantification, and number of electrons and protons involved in electro­chemical reactions were determined. The ease of fabrication, cost-effectiveness, and robust performance of poly(asp)-DSS-MCPE make it a promising electrocatalyst for detecting DA and other bioactive molecules, without interference from interfering molecules.

Zitieren

APA

Rajendrachari, S., Nagarajappa, H., Neelalochana, V. D., Shivaraju, R. G., Demir, E., Antherjanam, S., & Karaoglanli, K. E. (2026). Poly(asparagine)-modified duplex stainless steel composite carbon paste electrode for selective electrochemical detection of dopamine. Journal of Electrochemical Science and Engineering, 16. https://doi.org/10.5599/jese.3157

Vancouver

Rajendrachari S, Nagarajappa H, Neelalochana VD, Shivaraju RG, Demir E, Antherjanam S, et al. Poly(asparagine)-modified duplex stainless steel composite carbon paste electrode for selective electrochemical detection of dopamine. Journal of Electrochemical Science and Engineering. 2026;16. doi:10.5599/jese.3157

BibTeX
@article{Rajendrachari2026,
  author = {Rajendrachari, Shashanka and Nagarajappa, Hareesha and Neelalochana, Varun Donnakatte and Shivaraju, Rakshitha Gattavadipura and Demir, Ersin and Antherjanam, Santhy and Karaoglanli, Kazim Erden},
  title = {Poly(asparagine)-modified duplex stainless steel composite carbon paste electrode for selective electrochemical detection of dopamine},
  journal = {Journal of Electrochemical Science and Engineering},
  year = {2026},
  volume = {16},
  doi = {10.5599/jese.3157}
}
Kostenlos starten →