Y-Co metal-organic framework for sensitive electrochemical determination of doxorubicin hydrochloride
ADMET and DMPK · 18.12.2025 · 13 (6) · 3141
DOI: 10.5599/admet.3141 ↗Kurz gefasst
Fachartikel in der Zeitschrift ADMET and DMPK, online erschienen am 18.12.2025. Verfasst von Somayeh Mir und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, University of Sistan and Baluchestan, P.O. Box 98135-674, Zahedan, Iran. Die Arbeit wurde bisher 37-mal zitiert (Crossref) und nennt 55 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: University of Sistan and Baluchestan, Kerman University of Medical Sciences, Farhangian University.
Abstract (Originalsprache)
Background and purpose: Cancer represents a major challenge to public health; therefore, identifying doxorubicin hydrochloride (DOX·HCl) as an important chemotherapy drug holds considerable significance. Experimental approach: An electrochemical sensing strategy was designed for DOX·HCl determination by using Y-Co bimetallic metal-organic framework (Y-Co MOF) modified carbon paste electrode (CPE). The Y-Co-MOF was successfully prepared via the solvothermal method. Key results: Characterizations using field emission scanning electron microscopy, transmission electron microscopy, X-ray diffraction, Fourier transform infrared spectroscopy and energy-dispersive X-ray spectroscopy with elemental mapping images were used to evaluate the morphological features, crystalline structure, functional groups, and elemental composition of the Y-Co-MOF. From cyclic voltammetric studies, well-defined redox peaks of DOX·HCl with improved response peak currents at lower overpotentials were observed on the surface of Y-Co MOF/CPE compared to the unmodified CPE. This indicated that the as-prepared modified CPE has a strong and efficient redox capability toward DOX·HCl. Under the optimized parameters and conditions, the linear response range from differential pulse voltammetry measurements for DOX·HCl were 0.0025 to 100.0 µM, with a low limit of detection of 0.001 µM. Finally, the ability of the designed sensing platform to determine the amounts of DOX·HCl in the injection sample was studied and it has been observed a high and efficient ability with satisfactory values of recovery and relative standard deviation. Conclusion: This analytical approach offers a useful means for the analysis of pharmaceutical formulations, providing potential advantages in cancer therapy.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Chemistry, University of Sistan and Baluchestan, P.O. Box 98135-674, Zahedan, Iran.
- Department of Chemistry Education, Farhangian University, P.O. Box 14665-889, Tehran, Iran.
- Research Center of Tropical and Infectious Diseases, Kerman University of Medical Sciences, Kerman, Iran.
- Environment Department, Institute of Science and High Technology and Environmental Sciences, Graduate University of Advanced Technology, Kerman, Iran.
ORCID-Profile: Niloufar Akbarzadeh Torbati, Vahid Amani, Hadi Beitollahi
Förderung
- University of Sistan and Baluchestan
- Kerman University of Medical Sciences
- Farhangian University
Zitieren
APA
Mir, S., Torbati, N. A., Amani, V., Tajik, S., & Beitollahi, H. (2025). Y-Co metal-organic framework for sensitive electrochemical determination of doxorubicin hydrochloride. ADMET and DMPK, 13(6), 3141. https://doi.org/10.5599/admet.3141
Vancouver
Mir S, Torbati NA, Amani V, Tajik S, Beitollahi H. Y-Co metal-organic framework for sensitive electrochemical determination of doxorubicin hydrochloride. ADMET and DMPK. 2025;13(6):3141. doi:10.5599/admet.3141
BibTeX
@article{Mir2025,
author = {Mir, Somayeh and Torbati, Niloufar Akbarzadeh and Amani, Vahid and Tajik, Somayeh and Beitollahi, Hadi},
title = {Y-Co metal-organic framework for sensitive electrochemical determination of doxorubicin hydrochloride},
journal = {ADMET and DMPK},
year = {2025},
volume = {13},
number = {6},
pages = {3141},
doi = {10.5599/admet.3141}
}
EUVIMED