Estimating TPR₂₀,₁₀ Under Non-Reference Conditions Using a Geometric Sequence Approach
Atom Indonesia · 31.03.2026 · 52 (1) · 73-79
DOI: 10.55981/aij.2026.1564 ↗Kurz gefasst
Fachartikel in der Zeitschrift Atom Indonesia, online erschienen am 31.03.2026. Verfasst von F. A. Rizaldi und 4 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-SA 4.0).
Abstract (Originalsprache)
An alternative approach to estimate the Tissue Phantom Ratio (TPR) at depths of 20 cm and 10 cm (TPR₂₀,₁₀) under non-reference conditions is required to address situations where a 10 × 10 cm² field size is not achievable on a specific Linear Accelerator (LINAC) during a beam quality test. This study aims to estimate the TPR20,10 under non-reference conditions using a geometric sequence approach, and to compare it with the TPR₂₀,₁₀ under non-reference conditions estimated using the Sauer method, the Palmas method, a linear fit approach, as well as with the TPR₂₀,₁₀ under reference conditions calculated using the TRS-398 protocol. The first step in this study was measuring the percentage depth dose (PDD), D20cm, and D10cm with field size variations from 4 × 4 cm² to 10 × 10 cm² for both 6 MV and 10 MV X-ray beams. The PDD were used to estimate the TPR₂₀,₁₀ using a geometric sequence approach, the Sauer method, the Palmans method, and a linear fit approach, and to calculate the TPR₂₀,₁₀ using the TRS-398 protocol. The D20cm and D10cm were also used to calculate the TPR₂₀,₁₀ using the TRS-398 protocol. The TPR₂₀,₁₀ for 6 MV and 10 MV X-ray beams estimated using the geometric sequence approach were 0.683 ± 0.004 and 0.742 ± 0.005, respectively. The level of precision that could be reached by the geometric sequence approach is potentially equivalent to the TRS-398 protocol, the Sauer method, the Palmans method, and the linear fit approach. The TPR₂₀,₁₀ for 6 MV and 10 MV X-ray beams estimated using the geometric sequence method did not show a significant difference compared with the TPR₂₀,₁₀ calculated using the TRS-398 protocol. However, the TPR₂₀,₁₀ for 6 MV and 10 MV X-ray beams estimated using the geometric sequence approach showed a significant difference compared with those TPR₂₀,₁₀ estimated using the Sauer method and the Palmans method.
Zitieren
APA
Rizaldi, F. A., Herwiningsih, S., Widodo, C. S., Hentihu, F. K., & Anto, A. K. (2026). Estimating TPR₂₀,₁₀ Under Non-Reference Conditions Using a Geometric Sequence Approach. Atom Indonesia, 52(1), 73-79. https://doi.org/10.55981/aij.2026.1564
Vancouver
Rizaldi FA, Herwiningsih S, Widodo CS, Hentihu FK, Anto AK. Estimating TPR₂₀,₁₀ Under Non-Reference Conditions Using a Geometric Sequence Approach. Atom Indonesia. 2026;52(1):73-79. doi:10.55981/aij.2026.1564
BibTeX
@article{Rizaldi2026,
author = {Rizaldi, F. A. and Herwiningsih, S. and Widodo, C. S. and Hentihu, F. K. and Anto, A. K.},
title = {Estimating TPR₂₀,₁₀ Under Non-Reference Conditions Using a Geometric Sequence Approach},
journal = {Atom Indonesia},
year = {2026},
volume = {52},
number = {1},
pages = {73--79},
doi = {10.55981/aij.2026.1564}
}
EUVIMED