Diagnostic accuracy of TB-LAMP and smear microscopy for pulmonary TB in active case finding

A Shimouchi, R S Gopali, B Maharjan, Y Shrestha, Y Hirano, N P Shah, P Ghimire, P Shrestha, K Okada

IJTLD Open · 2026-03 · 3 (3) · 151-156

DOI: 10.5588/ijtldopen.25.0557 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IJTLD Open, online erschienen am 01.03.2026. Verfasst von A Shimouchi und 8 weiteren Autor:innen. Beteiligte Einrichtung: Japan Anti-Tuberculosis Association (JATA), Nepal Office, Kathmandu, Nepal. Die Arbeit nennt 20 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND In Nepal, most sputum tests are done with smear microscopy. However, in order to increase case detection by active case finding (ACF), more sensitive bacteriological test should be used. METHODS Presumptive TB cases aged five and over detected by symptomatic screening and X-ray screening for pulmonary TB were included in the study. Smear microscopy, loop-mediated isothermal-amplification for TB (TB-LAMP), and Xpert MTB/RIF (Xpert) were performed as part of routine TB diagnostic procedure in ACF. We compared the diagnostic accuracy of TB-LAMP and smear microscopy by using Xpert as the microbiological reference standard. RESULTS Among 653 samples, sensitivity, specificity, and kappa value of smear microscopy and TB-LAMP were 30.5% (95% confidence interval [CI]: 21.6–41.1), 99.8% (95% CI: 99.0–99.9), 0.43 (95% CI: 0.36–0.49) and 72.0% (95% CI: 61.4–80.5), 99.7% (95% CI: 98.7–99.9), 0.80 (95% CI: 0.73–0.88), respectively. Sensitivity of TB-LAMP (72.0%) was 41.5% higher than that of smear microscopy (30.5%) ( P < 0.01). Sensitivity of TB-LAMP and smear microscopy was high for multibacillary TB. Sensitivity of TB-LAMP was substantially higher than that of smear microscopy for paucibacillary TB. CONCLUSION Sensitivity of TB-LAMP was much higher than that of smear microscopy in ACF. TB-LAMP is recommended to replace smear microscopy in ACF to increase the detection of bacteriologically confirmed pulmonary TB.

Schlagwörter

Stichwörter der Autor:innen

NepalX-ray screeningbacteriological testearly case detectionpresumptive TBsymptomatic screeningtuberculosis

Autor:innen und Institutionen

  • Japan Anti-Tuberculosis Association (JATA), Nepal Office, Kathmandu, Nepal.
  • Research Institute of Tuberculosis, JATA, Tokyo, Japan.
  • Japan-Nepal Health and Tuberculosis Research Association, Kathmandu, Nepal.
  • Department of International Program, JATA, Tokyo, Japan.
  • National Tuberculosis Control Center, Thimi, Nepal.
  • National Academy of Medical Sciences, Bir Hospital, Kathmandu, Nepal.

Zitieren

APA

Shimouchi, A., Gopali, R. S., Maharjan, B., Shrestha, Y., Hirano, Y., Shah, N. P., Ghimire, P., Shrestha, P., & Okada, K. (2026). Diagnostic accuracy of TB-LAMP and smear microscopy for pulmonary TB in active case finding. IJTLD Open, 3(3), 151-156. https://doi.org/10.5588/ijtldopen.25.0557

Vancouver

Shimouchi A, Gopali RS, Maharjan B, Shrestha Y, Hirano Y, Shah NP, et al. Diagnostic accuracy of TB-LAMP and smear microscopy for pulmonary TB in active case finding. IJTLD Open. 2026;3(3):151-156. doi:10.5588/ijtldopen.25.0557

BibTeX
@article{Shimouchi2026,
  author = {Shimouchi, A and Gopali, R S and Maharjan, B and Shrestha, Y and Hirano, Y and Shah, N P and Ghimire, P and Shrestha, P and Okada, K},
  title = {Diagnostic accuracy of TB-LAMP and smear microscopy for pulmonary TB in active case finding},
  journal = {IJTLD Open},
  year = {2026},
  volume = {3},
  number = {3},
  pages = {151--156},
  doi = {10.5588/ijtldopen.25.0557}
}
Kostenlos starten →