Evaluation of testing face-mask filter samples with LAMP shows high rates of detection in pulmonary TB
The International Journal of Tuberculosis and Lung Disease · 2024
DOI: 10.5588/ijtld.24.0190 ↗Kurz gefasst
Fachartikel in der Zeitschrift The International Journal of Tuberculosis and Lung Disease, 2024. Verfasst von T Kodama und 12 weiteren Autor:innen. Beteiligte Einrichtung: Respiratory Disease Center, Fukujuji Hospital, Japan Anti-Tuberculosis Association (JATA), Tokyo, Japan;, Department of Basic Mycobacteriosis, Gradua…. Hauptthemen laut MEDLINE: Tuberculosis, Pulmonary, Mycobacterium tuberculosis, Nucleic Acid Amplification Techniques, Filtration. Die Arbeit wurde bisher 2-mal zitiert (Crossref).
Abstract (Originalsprache)
BACKGROUND
Detection of Mycobacterium tuberculosis (MTB) in bioaerosols derived from patients with active pulmonary TB is a potential alternative diagnostic method for patients with presumed TB who cannot expectorate sputum.
OBJECTIVE
To assess the efficacy of a bioaerosol particle collection method to capture MTB and diagnose TB.
METHODS
A mask-like filter holder (3D mask) with a water-soluble gelatine filter (GF) and one containing a water-insoluble polypropylene filter (PPF) were prepared. Eligible patients wore the 3D mask with GF or PPF within 3 days of starting anti-TB drugs. The GF and PPF filters were collected after 2 and 8 h. DNA was extracted from the filter samples and tested using loop-mediated isothermal amplification (LAMP).
RESULTS
Filter samples were collected from 57 and 20 patients with and without active pulmonary TB, respectively. The GF and PPF sensitivity was 76.2% and 83.3%, respectively. The specificity of both methods was 100%. Of the 57 patients diagnosed with non-expectorated sputum samples, including suction phlegm, gastric lavage, and bronchial lavage fluid, 55.6% and 50.0% were positive by GF and PPF, respectively.
CONCLUSION
We present a 3D mask filter sampling method for exhaled bioaerosol particles that can be used in clinical practice to diagnose patients with presumed TB.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Respiratory Disease Center, Fukujuji Hospital, Japan Anti-Tuberculosis Association (JATA), Tokyo, Japan;, Department of Basic Mycobacteriosis, Graduate School of Biomedical Sciences, Nagasaki University, Nagasaki, Japan.
- Department of Mycobacterium Reference and Research, Research Institute of Tuberculosis, JATA, Kiyose, Tokyo, Japan.
- Department of Clinical Laboratory, Fukujuji Hospital, JATA, Tokyo, Japan.
- Respiratory Disease Center, Fukujuji Hospital, Japan Anti-Tuberculosis Association (JATA), Tokyo, Japan.
- Department of Basic Mycobacteriosis, Graduate School of Biomedical Sciences, Nagasaki University, Nagasaki, Japan;, Department of Mycobacterium Reference and Research, Research Institute of Tuberculosis, JATA, Kiyose, T…
Zitieren
APA
Kodama, T., Chikamatsu, K., Kamada, K., Mizuno, K., Morishige, Y., Igarashi, Y., Osugi, A., Aono, A., Murase, Y., Okumura, M., Yoshiyama, T., Takaki, A., & Mitarai, S. (2024). Evaluation of testing face-mask filter samples with LAMP shows high rates of detection in pulmonary TB. The International Journal of Tuberculosis and Lung Disease. https://doi.org/10.5588/ijtld.24.0190
Vancouver
Kodama T, Chikamatsu K, Kamada K, Mizuno K, Morishige Y, Igarashi Y, et al. Evaluation of testing face-mask filter samples with LAMP shows high rates of detection in pulmonary TB. The International Journal of Tuberculosis and Lung Disease. 2024. doi:10.5588/ijtld.24.0190
BibTeX