The validity of the VO2 master pro for assessing VO2max and running economy in trained runners
Scientific Journal of Sport and Performance · 10.07.2026 · 5 (4) · 598
DOI: 10.55860/mzvi6493 ↗Kurz gefasst
Fachartikel in der Zeitschrift Scientific Journal of Sport and Performance, online erschienen am 10.07.2026. Verfasst von Trace A. Domny und 6 weiteren Autor:innen. Die Arbeit nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-SA 4.0).
Abstract (Originalsprache)
Purpose
This study assessed agreement between the portable VO₂ Master Pro (VM) and a non‑portable metabolic cart (NP) for measuring VO2max and running economy (RE).
Methods
Fourteen endurance‑trained runners (9 female, 5 male; age 24.7 ± 5.0 y) completed four randomized crossover trials: two VO2max tests and two RE sessions using VM or NP. RE consisted of four 5‑min bouts at 100%, 90%, 80%, and 70% of personal best 5‑km pace. Agreement was evaluated using paired t‑tests, intraclass correlation coefficients (ICC), standard error of measurement (SEM), coefficient of variation (CV), and Bland–Altman analysis.
Results
VM significantly overestimated relative VO2max compared with NP (65.4 ± 7.3 vs 53.5 ± 5.2 ml·kg⁻¹·min⁻¹, p < .001), with weak reliability (ICC = 0.46), high SEM (2.6 ml·kg⁻¹·min⁻¹), and unacceptable CV (14.1%). Mean bias was 11.9 ± 7.1 ml·kg⁻¹·min⁻¹. Maximal ventilation (VE) showed moderate agreement (ICC = 0.81; CV = 8.3%). Similar trends were observed across all RE intensities, with modest VO₂ agreement (ICC = 0.60–0.72) and stronger VE agreement (ICC = 0.87–0.93).
Conclusion
VM substantially overestimates VO₂ and demonstrates poor agreement with NP, limiting its utility as a replacement device. Greater agreement for VE suggests oxygen sensing as a primary source of error.
Zitieren
APA
Domny, T. A., Phillips, A. D., Tibbs, K. L., Gilmore, B. M., Phillips, J. P., O'Neal, E. K., & Andre, T. L. (2026). The validity of the VO2 master pro for assessing VO2max and running economy in trained runners. Scientific Journal of Sport and Performance, 5(4), 598. https://doi.org/10.55860/mzvi6493
Vancouver
Domny TA, Phillips AD, Tibbs KL, Gilmore BM, Phillips JP, O'Neal EK, et al. The validity of the VO2 master pro for assessing VO2max and running economy in trained runners. Scientific Journal of Sport and Performance. 2026;5(4):598. doi:10.55860/mzvi6493
BibTeX
@article{Domny2026,
author = {Domny, Trace A. and Phillips, Asha D. and Tibbs, Katherine L. and Gilmore, Brooke M. and Phillips, Julia P. and O'Neal, Eric K. and Andre, Thomas L.},
title = {The validity of the VO2 master pro for assessing VO2max and running economy in trained runners},
journal = {Scientific Journal of Sport and Performance},
year = {2026},
volume = {5},
number = {4},
pages = {598},
doi = {10.55860/mzvi6493}
}
EUVIMED