Treadmill-based submaximal VO₂ estimation in patients with coronary artery disease: can a model derived from healthy individuals be valid?
Turkish Journal of Medical Sciences · 15.08.2025 · 55 (4) · 930-939
DOI: 10.55730/1300-0144.6046 ↗Kurz gefasst
Fachartikel in der Zeitschrift Turkish Journal of Medical Sciences, online erschienen am 15.08.2025. Verfasst von Levent Karataş und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physical Medicine and Rehabilitation, Faculty of Medicine, Gazi University, Ankara, Turkiye. Hauptthemen laut MEDLINE: Coronary Artery Disease, Exercise Test, Oxygen Consumption. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background/aim: Existing treadmill-based VO₂ prediction models may not accurately estimate submaximal VO₂ in patients with coronary artery disease (CAD), as they are often derived from healthy populations. This study aimed to develop and validate a submaximal VO₂ prediction model derived from healthy individuals and tested for generalizability in CAD patients by incorporating clinically relevant parameters. Materials and methods: A retrospective analysis was conducted with 101 participants (54 healthy, 47 CAD patients) undergoing cardiopulmonary exercise testing using the modified Bruce protocol. To better represent the submaximal VO₂ reached during exercise, the average VO₂ in the last minute of each stage was used. The model was developed using data from healthy individuals and subsequently validated in the CAD cohort. A linear mixed-effects model was employed to predict VO₂ based on speed, grade, and other confounders, including peak VO₂, body weight, and body mass index (BMI). The model’s performance was evaluated and compared with previously published equations using Bland–Altman plots, mean absolute error (MAE), root mean square error (RMSE), and Lin’s concordance correlation coefficient (CCC).
Results
The final model, including speed, grade, and peak VO2, achieved an R² of 0.83 (95% CI: 0.79, 0.86; f² = 4.88). For CAD patients, the predicted-actual VO₂ difference was –0.05 ± 1.8 mL/kg/min, with MAE and RMSE values of 1.4 and 1.8 mL/kg/min, respectively. The model outperformed reference equations, achieving the highest accuracy (CCC = 0.923) and minimal bias. Incorporating peak VO₂ effectively accounted for exercise response differences between healthy individuals and CAD patients.
Conclusion
A submaximal VO₂ estimation model derived from healthy individuals and validated in CAD patients demonstrated high accuracy. Incorporating peak VO₂ effectively bridged physiological differences, supporting individualized exercise prescriptions in cardiac rehabilitation. However, larger prospective cohorts are warranted to confirm external validity.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Physical Medicine and Rehabilitation, Faculty of Medicine, Gazi University, Ankara, Turkiye.
ORCID-Profile: Levent Karataş, Esra Sena Orbak Yenidünya, Nesrin Demirsoy
Zitieren
APA
Karataş, L., Orbak Yenidünya, E. S., & Demirsoy, N. (2025). Treadmill-based submaximal VO₂ estimation in patients with coronary artery disease: can a model derived from healthy individuals be valid?. Turkish Journal of Medical Sciences, 55(4), 930-939. https://doi.org/10.55730/1300-0144.6046
Vancouver
Karataş L, Orbak Yenidünya ES, Demirsoy N. Treadmill-based submaximal VO₂ estimation in patients with coronary artery disease: can a model derived from healthy individuals be valid?. Turkish Journal of Medical Sciences. 2025;55(4):930-939. doi:10.55730/1300-0144.6046
BibTeX
@article{Karata2025,
author = {Karataş, Levent and Orbak Yenidünya, Esra Sena and Demirsoy, Nesrin},
title = {Treadmill-based submaximal VO₂ estimation in patients with coronary artery disease: can a model derived from healthy individuals be valid?},
journal = {Turkish Journal of Medical Sciences},
year = {2025},
volume = {55},
number = {4},
pages = {930--939},
doi = {10.55730/1300-0144.6046}
}
EUVIMED