EUVIMEDEUVIMED entdecken
VergleichsstudieValidierungsstudieOpen Access · CC BY 4.0

Evaluation and validation of 3D-printed anatomical urinary system model and virtual reality RIRS simulators in RIRS training: a comparative study

Mehmet Ezer iD, Tahsin Batuhan Aydoğan iD, Lazaros Tzelves iD, Andreas Skolarikos iD, Mehmet Uslu iD, Kemal Sarica iD, Emre Huri iD

Turkish Journal of Medical Sciences · 20.06.2025 · 55 (3) · 733-742

DOI: 10.55730/1300-0144.6022 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Turkish Journal of Medical Sciences, online erschienen am 20.06.2025. Verfasst von Mehmet Ezer und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Urology, School of Medicine, Kafhas University, Kars, Turkiye. Hauptthemen laut MEDLINE: Printing, Three-Dimensional, Virtual Reality, Models, Anatomic, Simulation Training. Die Arbeit wurde bisher 3-mal zitiert (Crossref). Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background/aim: This study evaluates the use of a 3D-printed anatomical urinary system model (3D-AUSM) and a Virtual Reality RIRS Simulator (VRRS), for training in RIRS, based on real user feedback. Materials and methods: The 3D-AUSM was created using cadaver CT and MRI scans, and the data was transferred to a VR environment for simulation. A total of 43 inexperienced urology trainees participated in the theoretical phase of the RIRS training program. Of these, 32 trainees (Group T) who passed a proficiency exam proceeded to the hands-on training phase with the 3D-AUSM and VRRS models. Additionally, 17 experienced surgeons (Group S) were included in the study for validation purposes. Skill scores and procedure times were recorded for both groups, and participants completed surveys to evaluate content, face, and construct validation of the models.

Results

Group S completed the procedures faster and achieved higher skill scores than Group T in both models. Group T, however, performed better with VRRS compared to 3D-AUSM. The most challenging steps for both groups were “exposing the intrarenal collecting system” and “relocating the stone”. Both groups rated the models highly for content and face validation, though experienced surgeons gave lower overall satisfaction scores to VRRS compared to 3D-AUSM.

Conclusion

3D-printed models and VR simulators are safe, cost-effective tools for developing essential surgical skills. While 3D-AUSM provides realistic anatomical feedback, VRRS offers unlimited practice opportunities. Both models are valuable in surgical education, promoting standardized, effective training.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Printing, Three-DimensionalVirtual RealityModels, AnatomicSimulation TrainingUrologyUrinary TractHumansClinical CompetenceMaleCadaver

Stichwörter der Autor:innen

3D printingRIRSsimulationsurgical trainingvirtual reality

Autor:innen und Institutionen

  • Department of Urology, School of Medicine, Kafhas University, Kars, Turkiye.
  • Department of Urology, Kartal Dr. Lütfi Kırdar City Hospital, İstanbul, Turkiye.
  • Department of Uro-Oncology, University College of London Hospitals, UCLH, London, United Kingdom.
  • Second Department of Urology, Sismanoglio Hospital, Athens, Greece.
  • Department of Urology, Sancaktepe Şehit Prof. Dr. İlhan Varank Training and Research Hospital, İstanbul, Turkiye.
  • Department of Urology, Biruni University Medical School, İstanbul, Turkiye.

ORCID-Profile: Mehmet Ezer, Tahsin Batuhan Aydoğan, Lazaros Tzelves, Andreas Skolarikos, Mehmet Uslu, Kemal Sarica, Emre Huri

Zitieren

APA

Ezer, M., Aydoğan, T. B., Tzelves, L., Skolarikos, A., Uslu, M., Sarica, K., & Huri, E. (2025). Evaluation and validation of 3D-printed anatomical urinary system model and virtual reality RIRS simulators in RIRS training: a comparative study. Turkish Journal of Medical Sciences, 55(3), 733-742. https://doi.org/10.55730/1300-0144.6022

Vancouver

Ezer M, Aydoğan TB, Tzelves L, Skolarikos A, Uslu M, Sarica K, et al. Evaluation and validation of 3D-printed anatomical urinary system model and virtual reality RIRS simulators in RIRS training: a comparative study. Turkish Journal of Medical Sciences. 2025;55(3):733-742. doi:10.55730/1300-0144.6022

BibTeX
@article{Ezer2025,
  author = {Ezer, Mehmet and Aydoğan, Tahsin Batuhan and Tzelves, Lazaros and Skolarikos, Andreas and Uslu, Mehmet and Sarica, Kemal and Huri, Emre},
  title = {Evaluation and validation of 3D-printed anatomical urinary system model and virtual reality RIRS simulators in RIRS training: a comparative study},
  journal = {Turkish Journal of Medical Sciences},
  year = {2025},
  volume = {55},
  number = {3},
  pages = {733--742},
  doi = {10.55730/1300-0144.6022}
}
Kostenlos starten →