EUVIMEDEUVIMED entdecken
Open Access

Individualized hemodialysis: Is similar hemodialysis adequacy possible using less water?

Ali Aktaş iD, Hakan Özer iD, İsmail Baloğlu iD, Halil Zeki Tonbul iD, İbrahim Güney iD, Nedim Yılmaz Selçuk iD

Turkish Journal of Medical Sciences · 12.12.2023 · 53 (6) · 1863-1869

DOI: 10.55730/1300-0144.5756 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Turkish Journal of Medical Sciences, online erschienen am 12.12.2023. Verfasst von Ali Aktaş und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Internal Medicine, Faculty of Meram Medicine, Necmettin Erbakan University, Konya, Turkiye. Hauptthemen laut MEDLINE: Renal Dialysis. Die Arbeit wurde bisher 4-mal zitiert (Crossref). Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background and aim: There are over 60,000 hemodialysis (HD) patients in Türkiye, and the number of patients is increasing yearly. Dialysate flow rate (Qd) is a factor in HD adequacy. Approximately 150 L of water are consumed per session to prepare the dialysate. We aimed to investigate whether HD effectiveness can be achieved at a low Qd in different patient groups for the purpose of saving water. Materials and methods: This prospective study included 81 HD patients from 2 centers. The patients underwent an aggregate total of 486 HD sessions, including 3 sessions at a Qd of 500 mL/min and 3 sessions at a Qd of 300 mL/min for each patient. We used online Kt/V readings recorded at the end of each dialysis session to compare the effectiveness of these 2 types of HD session performed at a different Qd.

Results

The online Kt/V readings were similar between the standard (500) and low (300) Qd HD (1.51 ∓ 0.41 and 1.49 ∓ 0.44, respectively, p = 0.069). In the subgroup analyses, men had higher online Kt/V values at the standard Qd compared to the low Qd (1.35 ∓ 0.30 and 1.30 ∓ 0.32, respectively, p = 0.019), but the Kt/V values were not different for women. While the low Qd did not reduce online Kt/V in patients using small surface area dialysis membranes (1.75 ∓ 0.35 for 300 Qd and 1.75 ∓ 0.32 for 500 Qd, p = 0.931), it was associated with reduced online Kt/V in patients using large surface area dialysis membranes (1.12 ∓ 0.25 for 300 Qd and 1.17 ∓ 0.24 for 500 Qd, p = 0.006). The low Qd did not result in differences in online Kt/V among low-weight patients. However, online Kt/V values were better with the standard Qd in patients weighing 65 kg and above.

Conclusion

In our study, dialysis adequacy at a reduced dialysate flow was not inferior for women, patients with low body weight, or patients using small surface area membranes. Individualized HD at a reduced Qd of 300 mL/min in eligible patients can save 48 L of water per HD session and an average of 7500 L of water per year.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Renal DialysisHumansFemaleMaleProspective StudiesMiddle AgedAgedWaterAdultDialysis SolutionsKidney Failure, Chronic

Stichwörter der Autor:innen

Hemodialysisdialysate flow ratedialysis adequacyonline Kt/V

Substanzen

WaterDialysis Solutions

Autor:innen und Institutionen

  • Department of Internal Medicine, Faculty of Meram Medicine, Necmettin Erbakan University, Konya, Turkiye.
  • Division of Nephrology, Department of Internal Medicine, Konya City Hospital, Konya, Turkiye.
  • Division of Nephrology, Department of Internal Medicine, Faculty of Meram Medicine, Necmettin Erbakan University, Konya, Turkiye.

ORCID-Profile: Ali Aktaş, Hakan Özer, İsmail Baloğlu, Halil Zeki Tonbul, İbrahim Güney, Nedim Yılmaz Selçuk

Zitieren

APA

Aktaş, A., Özer, H., Baloğlu, İ., Tonbul, H. Z., Güney, İ., & Selçuk, N. Y. (2023). Individualized hemodialysis: Is similar hemodialysis adequacy possible using less water?. Turkish Journal of Medical Sciences, 53(6), 1863-1869. https://doi.org/10.55730/1300-0144.5756

Vancouver

Aktaş A, Özer H, Baloğlu İ, Tonbul HZ, Güney İ, Selçuk NY. Individualized hemodialysis: Is similar hemodialysis adequacy possible using less water?. Turkish Journal of Medical Sciences. 2023;53(6):1863-1869. doi:10.55730/1300-0144.5756

BibTeX
@article{Akta2023,
  author = {Aktaş, Ali and Özer, Hakan and Baloğlu, İsmail and Tonbul, Halil Zeki and Güney, İbrahim and Selçuk, Nedim Yılmaz},
  title = {Individualized hemodialysis: Is similar hemodialysis adequacy possible using less water?},
  journal = {Turkish Journal of Medical Sciences},
  year = {2023},
  volume = {53},
  number = {6},
  pages = {1863--1869},
  doi = {10.55730/1300-0144.5756}
}
Kostenlos starten →