Adjustable bone plate: from bench to operating room
Turkish Journal of Medical Sciences · 26.10.2023 · 53 (5) · 1379-1386
DOI: 10.55730/1300-0144.5704 ↗Kurz gefasst
Fachartikel in der Zeitschrift Turkish Journal of Medical Sciences, online erschienen am 26.10.2023. Verfasst von Gazi Huri und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedics and Traumatology, Faculty of Medicine, Hacettepe University, Ankara, Turkiye. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Background/aim: We have designed an adjustable bone plate (ABP) which allows bone shortening and lengthening after fixation, which is a property not present in any of the plate systems available today. The aim of the current study was to examine the new ABP?s segmental bone transfer capability for the treatment of a segmental bone defect in an animal model. Materials and methods: Five sheep had ABPs attached to 10 of their tibias and bone defects of 15 mm in size were created. The pinion mechanism was moved with a manual screwdriver at a rate of 1mm/day for 15 days starting 3 days postoperatively. The animals were euthanized 3 months postoperatively, and the defect site and the transferred segment were evaluated by radiological and histological examination.
Results
The radiological results revealed successful transfers of 14.6 ± 1.2 mm of bone segment on all tibia defects without any complications. The histological evaluation showed new bone formation in both the extension and the docking sites. No rupture or breakage was observed within the plates.
Conclusion
We have presented the potential of a new generation ABP for use in segmental bone transfer in an animal model as well as for future clinical applications.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopedics and Traumatology, Faculty of Medicine, Hacettepe University, Ankara, Turkiye.
- Department of Orthopedics and Traumatology, Faculty of Medicine, Çukurova University Adana, Turkiye.
- Department of Biomedical Engineering, Faculty of Engineering, Ankara University, Ankara, Turkiye.
- Department of Histology and Embryology, Faculty of Medicine, Çukurova University Adana, Turkiye.
- Department of Orthopedics and Traumatology, Faculty of Medicine, Ufuk University, Ankara, Turkiye.
ORCID-Profile: Gazi Huri, Erdi Özdemir, Ömer Sunkar Biçer, Pınar Yilgör Huri, Sait Polat, Tuğçe Sapmaz, Mahmut Nedim Doral
Zitieren
APA
Huri, G., Özdemir, E., Biçer, Ö. S., Yilgör Huri, P., Polat, S., Sapmaz, T., & Doral, M. N. (2023). Adjustable bone plate: from bench to operating room. Turkish Journal of Medical Sciences, 53(5), 1379-1386. https://doi.org/10.55730/1300-0144.5704
Vancouver
Huri G, Özdemir E, Biçer ÖS, Yilgör Huri P, Polat S, Sapmaz T, et al. Adjustable bone plate: from bench to operating room. Turkish Journal of Medical Sciences. 2023;53(5):1379-1386. doi:10.55730/1300-0144.5704
BibTeX
@article{Huri2023,
author = {Huri, Gazi and Özdemir, Erdi and Biçer, Ömer Sunkar and Yilgör Huri, Pınar and Polat, Sait and Sapmaz, Tuğçe and Doral, Mahmut Nedim},
title = {Adjustable bone plate: from bench to operating room},
journal = {Turkish Journal of Medical Sciences},
year = {2023},
volume = {53},
number = {5},
pages = {1379--1386},
doi = {10.55730/1300-0144.5704}
}
EUVIMED