Fachartikel in der Zeitschrift Asian Journal of Atmospheric Environment, online erschienen am 01.03.2021. Verfasst von Zikrilla Bobamuratovich Alimov und 2 weiteren Autor:innen. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Tokyo Dylec Corp., Japan International Cooperation Agency.
Abstract (Originalsprache)
This study presents the results of designing a low-cost air sampler for multi-component analysis of PM 2.5 . We developed a multi-channel air sampling device using sonic venturi (critical nozzle) that supplies a constant airflow rate of 16.7 L/min. The constant flow rate is achieved with a backpressure ratio of 0.8 or less with a nozzle diameter of 1.375 mm. The sampler halves the cost of comparable devices and simplifies the hardware by replacing the flow meters with critical nozzles. For quantitative evaluation, we measured the coefficient of variation (CV) of each component simultaneously collected five samples at various particulate matter concentrations. This sampler can use different types of filters such as polytetrafluoroethylene and quartz fiber filter at the same time. Meteorological conditions such as ambient temperature, relative humidity and atmospheric pressure did not seem to affect much the flow rate of the sampler. The CV of multi sample analysis for TSP and PM 2.5 concentrations in all sampling periods were less than 10%. CV of multi sample analysis for most of the major inorganic elements being within the range of 15% or less shows that the precision is sufficient for reliable measurement. We believe that the low-cost multiple air sampler will be used world-widely, and it can contribute to many researchers in both developed and developing countries.
Förderung
- Tokyo Dylec Corp.
- Japan International Cooperation Agency
Zitieren
APA
Alimov, Z. B., Kusakari, H., & Okuda, T. (2021). Development of A Low-cost Simultaneous Low Volume Air Sampler Controlled with Sonic Venturi. Asian Journal of Atmospheric Environment, 15(1). https://doi.org/10.5572/ajae.2020.072
Vancouver
Alimov ZB, Kusakari H, Okuda T. Development of A Low-cost Simultaneous Low Volume Air Sampler Controlled with Sonic Venturi. Asian Journal of Atmospheric Environment. 2021;15(1). doi:10.5572/ajae.2020.072
BibTeX
@article{Alimov2021,
author = {Alimov, Zikrilla Bobamuratovich and Kusakari, Hikaru and Okuda, Tomoaki},
title = {Development of A Low-cost Simultaneous Low Volume Air Sampler Controlled with Sonic Venturi},
journal = {Asian Journal of Atmospheric Environment},
year = {2021},
volume = {15},
number = {1},
doi = {10.5572/ajae.2020.072}
}
EUVIMED