EUVIMEDEUVIMED entdecken
Crossref

ANÁLISE COMPARATIVA DA EFICÁCIA DO ULTRASSOM MICROFOCADO LINEAR VERSUS PONTUAL NO REJUVENESCIMENTO FACIAL

Roseane Debora Barbosa Soares

Revista Científica Ipedss · 2026 · 06 (03)

DOI: 10.55703/27644006060305 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Revista Científica Ipedss, 2026. Verfasst von Roseane Debora Barbosa Soares.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Facial aging involves progressive changes in structural support, dermal quality, and skin firmness, driving the demand for minimally invasive procedures capable of promoting rejuvenation with safety and shorter recovery time. In this context, microfocused ultrasound has become a relevant technology in aesthetic dermatology and orofacial harmonization, as it induces thermal coagulation zones at specific depths, stimulates neocollagenesis, and promotes extracellular matrix remodeling. This study aimed to comparatively analyze the clinical efficacy and safety of microfocused ultrasound in linear and point modes for facial rejuvenation. This is a comparative study based on the analysis of mechanisms of action, application parameters, tissue response, and clinical outcomes associated with both technological modalities. The point mode demonstrates greater precision in the formation of thermal coagulation points and is particularly indicated for focal contraction of the superficial musculoaponeurotic system and for producing a lifting effect in areas that require greater anatomical control. Conversely, the linear mode provides a more homogeneous thermal distribution, favoring volumetric heating, reduction of localized adipose tissue, dermal tightening, and improvement of facial contour, with a possible reduction in discomfort and application time. The analysis shows that both modalities have a favorable safety profile, with predominantly mild and transient adverse events, such as localized erythema and edema. It is concluded that linear and point microfocused ultrasound have complementary applications in the management of facial aging, and the choice of technique should be guided by individualized anatomical assessment, degree of skin laxity, tissue thickness, and each patient’s therapeutic objectives. The association between personalized planning, technical expertise, and image-guided monitoring may increase outcome predictability and strengthen the safety of noninvasive aesthetic protocols. Keywords: Microfocused ultrasound; Facial rejuvenation; Skin laxity; Neocollagenesis; Orofacial harmonization.

Zitieren

APA

Soares, R. D. B. (2026). ANÁLISE COMPARATIVA DA EFICÁCIA DO ULTRASSOM MICROFOCADO LINEAR VERSUS PONTUAL NO REJUVENESCIMENTO FACIAL. Revista Científica Ipedss, 06(03). https://doi.org/10.55703/27644006060305

Vancouver

Soares RDB. ANÁLISE COMPARATIVA DA EFICÁCIA DO ULTRASSOM MICROFOCADO LINEAR VERSUS PONTUAL NO REJUVENESCIMENTO FACIAL. Revista Científica Ipedss. 2026;06(03). doi:10.55703/27644006060305

BibTeX
@article{Soares2026,
  author = {Soares, Roseane Debora Barbosa},
  title = {ANÁLISE COMPARATIVA DA EFICÁCIA DO ULTRASSOM MICROFOCADO LINEAR VERSUS PONTUAL NO REJUVENESCIMENTO FACIAL},
  journal = {Revista Científica Ipedss},
  year = {2026},
  volume = {06},
  number = {03},
  doi = {10.55703/27644006060305}
}
Kostenlos starten →