EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Can bedside ultrasound make pediatric intubation safer?

Luis Gustavo Machado Farias, Alan Cristian Cordeiro Siqueira, Kammilly Fernanda Alves dos Santos, Fernanda Marcondes Ribas, Edgardo Emilio Serra, Valeria Daniela Robles

BioSCIENCE · 06.03.2026 · 1

DOI: 10.55684/2026.84.en.e00005 ↗

Kurz gefasst

Fachartikel in der Zeitschrift BioSCIENCE, online erschienen am 06.03.2026. Verfasst von Luis Gustavo Machado Farias und 5 weiteren Autor:innen. Die Arbeit nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Rapid and accurate confirmation of endotracheal tube positioning and caliber is critical in pediatric practice. Traditional methods, such as radiography and capnography, have limitations related to time, radiation exposure, and the inability to assess depth or selectivity.

Objective

To map and synthesize the evidence on the use of ultrasonography (US) to confirm the positioning, depth, and caliber of the endotracheal tube in pediatric populations.

Method

Scoping review conducted according to the PRISMA-ScR guidelines. The PubMed, Embase, and Cochrane Library databases were searched in September 2025, with no language restriction. Clinical studies comparing US with radiography, capnography, bronchoscopy, or anatomical formulas were included. Those with samples smaller than ten participants, exclusively adult populations, or simulations without clinical data were excluded. Two independent reviewers screened and extracted the data. The findings were narratively synthesized in five domains: tracheal versus esophageal distinction, depth and selectivity, caliber estimation, time to confirmation, and reproducibility.

Results

Were included 23 studies published between 2010 and 2025, covering emergency, operating room, and pediatric intensive care settings. Ultrasonography generally showed sensitivity ≥ 90% and confirmation times of less than one minute.

Conclusion

Bedside ultrasound is an effective, rapid, and reproducible method for confirming the positioning and estimating the caliber of the endotracheal tube in pediatrics. Large-scale implementation requires standardization of protocols and structured training.

Zitieren

APA

Farias, L. G. M., Siqueira, A. C. C., Santos, K. F. A. D., Ribas, F. M., Serra, E. E., & Robles, V. D. (2026). Can bedside ultrasound make pediatric intubation safer?. BioSCIENCE, 1. https://doi.org/10.55684/2026.84.en.e00005

Vancouver

Farias LGM, Siqueira ACC, Santos KFAD, Ribas FM, Serra EE, Robles VD. Can bedside ultrasound make pediatric intubation safer?. BioSCIENCE. 2026:1. doi:10.55684/2026.84.en.e00005

BibTeX
@article{Farias2026,
  author = {Farias, Luis Gustavo Machado and Siqueira, Alan Cristian Cordeiro and Santos, Kammilly Fernanda Alves dos and Ribas, Fernanda Marcondes and Serra, Edgardo Emilio and Robles, Valeria Daniela},
  title = {Can bedside ultrasound make pediatric intubation safer?},
  journal = {BioSCIENCE},
  year = {2026},
  pages = {1},
  doi = {10.55684/2026.84.en.e00005}
}
Kostenlos starten →