Abstract (Originalsprache)

Objective

To determine the reference values found in a reference population, free of any thyroidal as well as non-thyroidal illnesses. Methods and Materials: Initially, 266 adult volunteers were included in the study from Mohi Uddin Islamic Medical College, and Mohi Uddin Teaching Hospital Mirpur Azad Jammu and Kashmir during 31st August 2022 to 30th August 2023., Pakistan after taking written informed consent. One hundred and twenty-four volunteers were selected (females 63; males 61) after exclusion of the volunteers with one or more of the exclusion criteria. Blood specimens were collected and analyzed for rT3, fT3, fT4 and TSH using Maglumi X8 (Snibe, China), an ABEI (N-(aminobutil)-N-(ethyl)-isoluminol) based analyzer at Pathology Laboratory MOTH.

Results

Reference values of rT3, fT3, fT4 and TSH were found to be 13.3 – 19.8 ng/dL (0.2 – 0.30 nmol/L); 2.65 - 4.15 pg/mL (4.08 - 6.39 pmol/L);10.6 - 16.2 pg/mL (13.64– 20.84 pmol/L) and 0.43 - 3.98 mIU/mL (0.43 – 3.98 mIU/L), respectively.

Conclusion

Reference values determined in our own population should be used when diagnosing and monitoring NTIS and other thyroid disorders Keywords: Free thyroxine (fT4), Free triiodothyronine (fT3), Non-Thyroidal illness Syndrome, Reverse triiodothyronine (rT3), Thyroid stimulating hormone (TSH)

Zitieren

APA

Ijaz, A., Shahid, F., Paracha, S. N., Habib, F., Shaukat, M. B., & Najeeb, S. (2026). Establishment of reference values of markers of non-thyroidal illness syndrome on a state-of-the-art fully automated ABEI-based chemiluminescence system. Pakistan Journal of Pathology, 37(2), 81-88. https://doi.org/10.55629/pakjpathol.v37i2.991

Vancouver

Ijaz A, Shahid F, Paracha SN, Habib F, Shaukat MB, Najeeb S. Establishment of reference values of markers of non-thyroidal illness syndrome on a state-of-the-art fully automated ABEI-based chemiluminescence system. Pakistan Journal of Pathology. 2026;37(2):81-88. doi:10.55629/pakjpathol.v37i2.991

BibTeX
@article{Ijaz2026,
  author = {Ijaz, Aamir and Shahid, Furqan and Paracha, Shamila Najeeb and Habib, Farzana and Shaukat, Muhammad Bilal and Najeeb, Sara},
  title = {Establishment of reference values of markers of non-thyroidal illness syndrome on a state-of-the-art fully automated ABEI-based chemiluminescence system},
  journal = {Pakistan Journal of Pathology},
  year = {2026},
  volume = {37},
  number = {2},
  pages = {81--88},
  doi = {10.55629/pakjpathol.v37i2.991}
}
Kostenlos starten →