EVALUATION AND MEASURE OF ACCURACY OF ICT, CLIA AND NAT FOR THE DETECTION OF HEPATITIS B, C AND HIV IN THE BLOOD DONORS ABSTRACT
Journal of Ayub Medical College Abbottabad · 2023
DOI: 10.55519/jamc-04-12757 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Ayub Medical College Abbottabad, 2023. Verfasst von Romana Irshad und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pathology. Hauptthemen laut MEDLINE: HIV Infections, Hepatitis B, Hepatitis C. Die Arbeit wurde bisher 2-mal zitiert (Crossref). Der Volltext ist frei zugänglich (Open Access, CC BY-ND 4.0).
Abstract (Originalsprache)
Background
A sensitive and specific donor screening strategy is essential for the prevention of transfusion-transmitted infections (TTI). The study was conducted to ascertain the comparative efficacy of ICT, CLIA and NAT methods.
Methods
This cross-sectional analytical study was conducted in Regional Blood Center Abbottabad, Pakistan from 1st April to 25 August 2022. 6233 donors were screened for Hep B, C, and HIV by testing simultaneously with ICT, CLIA and NAT.
Results
Active Hep B, C and HIV Infection was present in 0.51%, 0.28% and 0.00048% donors respectively. The sensitivity was found to be higher for HBV and HIV with CLIA as compared to ICT but was equal for HCV with both. whereas specificity was the same with both CLIA and ICT for all three viruses. PPV was higher with ICT for HBV and HCV, but for HIV it was found higher by CLIA. NPV was higher for all three viruses by CLIA as compared to ICT.
Conclusion
In case rapid testing devices are used for the initial screening of blood in countries with limited resources, positive cases must be confirmed by CLIA and if possible, then by NAT because of missing cases in the window period and false positive cases.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Pathology.
- Department of Community Medicine, Ayub Medical College, Abbottabad.
- Institute of Basic Medical Sciences, KMU, Peshawar.
- Ayub Medical College, Abbottabad.
- Regional Blood Centre, Ayub Medical College & Teaching Hospital, Abbottabad, Pakistan.
Zitieren
APA
Irshad, R., Farooq, U., Ullah, I., Farooq, A., Shah, T., Gul, A., & Badshah, A. (2023). EVALUATION AND MEASURE OF ACCURACY OF ICT, CLIA AND NAT FOR THE DETECTION OF HEPATITIS B, C AND HIV IN THE BLOOD DONORS ABSTRACT. Journal of Ayub Medical College Abbottabad. https://doi.org/10.55519/jamc-04-12757
Vancouver
Irshad R, Farooq U, Ullah I, Farooq A, Shah T, Gul A, et al. EVALUATION AND MEASURE OF ACCURACY OF ICT, CLIA AND NAT FOR THE DETECTION OF HEPATITIS B, C AND HIV IN THE BLOOD DONORS ABSTRACT. Journal of Ayub Medical College Abbottabad. 2023. doi:10.55519/jamc-04-12757
BibTeX
@article{Irshad2023,
author = {Irshad, Romana and Farooq, Umer and Ullah, Ihsan and Farooq, Abeera and Shah, Tahir and Gul, Adeel and Badshah, Amir},
title = {EVALUATION AND MEASURE OF ACCURACY OF ICT, CLIA AND NAT FOR THE DETECTION OF HEPATITIS B, C AND HIV IN THE BLOOD DONORS ABSTRACT},
journal = {Journal of Ayub Medical College Abbottabad},
year = {2023},
doi = {10.55519/jamc-04-12757}
}
EUVIMED