EUVIMEDEUVIMED entdecken
Randomisierte kontrollierte Studie

12 MONTH'S ASSESSMENT OF CLINICAL EFFICACY OF RESIN MODIFIED GLASS IONOMER CEMENT AND FLOWABLE COMPOSITES IN RESTORATION OF NON-CARIOUS CERVICAL LESIONS, A RANDOMIZED CLINICAL TRIAL

Atikah Saghir, Tehmina Rehman, Bushra Irum, Zarah Afreen, Ammarah, Faisal Nawaz Nawaz

Journal of Ayub Medical College Abbottabad · 2023

DOI: 10.55519/jamc-01-10780 ↗

Kurz gefasst

Randomisierte kontrollierte Studie in der Zeitschrift Journal of Ayub Medical College Abbottabad, 2023. Verfasst von Atikah Saghir und 5 weiteren Autor:innen. Beteiligte Einrichtung: Foundation University College of Dentistry Islamabad. Hauptthemen laut MEDLINE: Composite Resins, Resins, Plant. Die Arbeit wurde bisher 3-mal zitiert (Crossref).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The objective of this study was to compare the clinical efficacy of Resin modified glass ionomer cement and Flowable composite in terms of retention, marginal adaptation and surface texture using United States Public Health Service criteria in non-carious cervical lesions measured over a period of one year.

Methods

A Randomized Clinical Trial is conducted with Informed consent on 60 patients who are randomly allocated into 2 groups with at least 2 Non-Carious Cervical Lesions in each. Group 1 is used for Flowable Composite while group 2 is used for resin modified glass ionomer cement. A recall is maintained to draw conclusions between two materials in terms of occurrence of marginal adaptation, retention and surface texture, to show which material is superior to other.

Results

Out of 30 restorations in 12 months follow up, only 19 found to be present in flowable composite group while in resin modified glass ionomer cement group, 28 are retained. Regarding margin integrity, Group 1 showed 21 intact margins whereas 23 margins were intact in group 2, while 18 and 25 showed smooth surface in flowable composite and Resin modified glass ionomer cement group respectively, on exploration.

Conclusion

It can be concluded from our study that Resin modified glass ionomer cement is superior to Flowable composite in terms of retention (p=0.005) and surface texture (p=0.045) in restoration of non-carious cervical lesion.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Composite ResinsResins, PlantUnited StatesHumansTreatment OutcomeGlass Ionomer Cements

Stichwörter der Autor:innen

Flowable Composite; Resin Modified Glass Ionomer CementNon-Carious Cervical Lesions; Marginal Adaptation; Retention; Surface texture

Substanzen

flowable hybrid compositeComposite ResinsResins, PlantGlass Ionomer Cements

Autor:innen und Institutionen

  • Foundation University College of Dentistry Islamabad.
  • Shahida Islam Medical & Dental College, Lodhran.
  • Khyber College of Dentistry, Peshawar.
  • Watim Dental College, Rawalpindi.
  • Military Dental Centre, Peshawar-Pakistan.

Zitieren

APA

Saghir, A., Rehman, T., Irum, B., Afreen, Z., Ammarah, & Nawaz, F. N. (2023). 12 MONTH'S ASSESSMENT OF CLINICAL EFFICACY OF RESIN MODIFIED GLASS IONOMER CEMENT AND FLOWABLE COMPOSITES IN RESTORATION OF NON-CARIOUS CERVICAL LESIONS, A RANDOMIZED CLINICAL TRIAL. Journal of Ayub Medical College Abbottabad. https://doi.org/10.55519/jamc-01-10780

Vancouver

Saghir A, Rehman T, Irum B, Afreen Z, Ammarah, Nawaz FN. 12 MONTH'S ASSESSMENT OF CLINICAL EFFICACY OF RESIN MODIFIED GLASS IONOMER CEMENT AND FLOWABLE COMPOSITES IN RESTORATION OF NON-CARIOUS CERVICAL LESIONS, A RANDOMIZED CLINICAL TRIAL. Journal of Ayub Medical College Abbottabad. 2023. doi:10.55519/jamc-01-10780

BibTeX
@article{Saghir2023,
  author = {Saghir, Atikah and Rehman, Tehmina and Irum, Bushra and Afreen, Zarah and Ammarah, Ammarah and Nawaz, Faisal Nawaz},
  title = {12 MONTH'S ASSESSMENT OF CLINICAL EFFICACY OF RESIN MODIFIED GLASS IONOMER CEMENT AND FLOWABLE COMPOSITES IN RESTORATION OF NON-CARIOUS CERVICAL LESIONS, A RANDOMIZED CLINICAL TRIAL},
  journal = {Journal of Ayub Medical College Abbottabad},
  year = {2023},
  doi = {10.55519/jamc-01-10780}
}
Kostenlos starten →