EUVIMEDEUVIMED entdecken
Crossref

Analisis Informasi Anatomi MSCT Head Dengan Variasi IBHC dan Kernel Untuk Mengurangi Artefak Beam Hardening

Yeti Kartikasari, Andrey Nino Kurniawan, Johan Kholid Wijaya

JRI (Jurnal Radiografer Indonesia) · 27.05.2026 · 9 (1) · 7-13

DOI: 10.55451/jri.v9i1.478 ↗

Kurz gefasst

Fachartikel in der Zeitschrift JRI (Jurnal Radiografer Indonesia), online erschienen am 27.05.2026. Verfasst von Yeti Kartikasari und 2 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Beam hardening artifact is one of the limitations of Multi-Slice Computed Tomography (MSCT), occurring due to changes in the X-ray spectrum when passing through dense materials. This artifact often appears in the head region, particularly in the posterior fossa, and can interfere with anatomical information and pixel intensity evaluation in MSCT images. The Iterative Beam Hardening Correction (IBHC) technique is used to iteratively reduce these artifacts during the post-processing stage. This study aims to determine the differences in anatomical information and beam hardening artifacts in head MSCT with variations of kernel and IBHC, and to identify the most optimal protocol.

Methods

This study utilized a quantitative-experimental design with a sample of 10 patients who underwent non-contrast MSCT head examinations at Oetomo Hospital, Bandung. The raw data were reconstructed into four variations: Hr40 + IBHC On, Hr40 + IBHC Off, Hc40 + IBHC On, and Hc40 + IBHC Off. Three radiologists evaluated the resulting images using a questionnaire to assess anatomical information (petrous bone, cerebellum, mid brain, pons) and beam hardening artifacts. Data analysis was performed using the Friedman test.

Results

The Friedman test showed a significant difference in overall anatomical information (p=0.000,p

Zitieren

APA

Kartikasari, Y., Kurniawan, A. N., & Wijaya, J. K. (2026). Analisis Informasi Anatomi MSCT Head Dengan Variasi IBHC dan Kernel Untuk Mengurangi Artefak Beam Hardening. JRI (Jurnal Radiografer Indonesia), 9(1), 7-13. https://doi.org/10.55451/jri.v9i1.478

Vancouver

Kartikasari Y, Kurniawan AN, Wijaya JK. Analisis Informasi Anatomi MSCT Head Dengan Variasi IBHC dan Kernel Untuk Mengurangi Artefak Beam Hardening. JRI (Jurnal Radiografer Indonesia). 2026;9(1):7-13. doi:10.55451/jri.v9i1.478

BibTeX
@article{Kartikasari2026,
  author = {Kartikasari, Yeti and Kurniawan, Andrey Nino and Wijaya, Johan Kholid},
  title = {Analisis Informasi Anatomi MSCT Head Dengan Variasi IBHC dan Kernel Untuk Mengurangi Artefak Beam Hardening},
  journal = {JRI (Jurnal Radiografer Indonesia)},
  year = {2026},
  volume = {9},
  number = {1},
  pages = {7--13},
  doi = {10.55451/jri.v9i1.478}
}
Kostenlos starten →