EUVIMEDEUVIMED entdecken
Crossref

ANALISIS INFORMASI ANATOMI DAN KUALITAS CITRA PADA SEKUENS T1 SE FAT SATURATION IRISAN SAGITAL OBLIQUE DENGAN VARIASI PHASE OVERSAMPLING PADA PEMERIKSAAN MRI ORBITA

Rachman Kusumadi, Emi Murniati, Siti Daryati

JRI (Jurnal Radiografer Indonesia) · 2018

DOI: 10.55451/jri.v1i2.20 ↗

Kurz gefasst

Fachartikel in der Zeitschrift JRI (Jurnal Radiografer Indonesia), 2018. Verfasst von Rachman Kusumadi und 2 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Aliasing artifacts often occur on MRI examinations Orbita sequence T1 SE Fat Saturation sagittal oblique slices. One way to eliminate aliasing artifacts is by setting Phase Oversampling (PO). The purpose of this study was to determine differences in anatomic information and image quality in the T1 SE sequence of oblique sagittal fat saturation slices with PO variations of orbital MRI examinations and to determine the value of PO variations that can produce optimal anatomic information and image quality in the sequences of T1 SE Fat Saturation slices sagittal oblique on Orbita MRI examination.

Method

This type of research is quantitative research with an experimental approach. The research subject is Orbita MRI imagery. The research sample consisted of Orbita MRI images obtained from 10 volunteers. Data obtained from SNR and CNR measurements to obtain image quality data, then the image results were assessed by respondents using questionnaires to obtain anatomic information data. The data obtained were analyzed using different tests in the SPSS application.

Results

The results showed that there were significant differences in the anatomy of the lens with aliasing artifact variations in PO 13%, while PO 52% and 91% had no aliasing artifacts. Optic nerve anatomy has a clear and well-defined image at PO 91% compared to PO 13% and 52%. Friedman test results on anatomic information on the anatomy of the Lens, superior Muscle rectus, and Optic nerve are significant with p-value 0.05, meaning there is no difference in anatomic information with variations in PO. Furthermore, the results of the study showed that there were differences in image quality (SNR and CNR) against PO variations with significance values ​​(p

Zitieren

APA

Kusumadi, R., Murniati, E., & Daryati, S. (2018). ANALISIS INFORMASI ANATOMI DAN KUALITAS CITRA PADA SEKUENS T1 SE FAT SATURATION IRISAN SAGITAL OBLIQUE DENGAN VARIASI PHASE OVERSAMPLING PADA PEMERIKSAAN MRI ORBITA. JRI (Jurnal Radiografer Indonesia). https://doi.org/10.55451/jri.v1i2.20

Vancouver

Kusumadi R, Murniati E, Daryati S. ANALISIS INFORMASI ANATOMI DAN KUALITAS CITRA PADA SEKUENS T1 SE FAT SATURATION IRISAN SAGITAL OBLIQUE DENGAN VARIASI PHASE OVERSAMPLING PADA PEMERIKSAAN MRI ORBITA. JRI (Jurnal Radiografer Indonesia). 2018. doi:10.55451/jri.v1i2.20

BibTeX
@article{Kusumadi2018,
  author = {Kusumadi, Rachman and Murniati, Emi and Daryati, Siti},
  title = {ANALISIS INFORMASI ANATOMI DAN KUALITAS CITRA PADA SEKUENS T1 SE FAT SATURATION IRISAN SAGITAL OBLIQUE DENGAN VARIASI PHASE OVERSAMPLING PADA PEMERIKSAAN MRI ORBITA},
  journal = {JRI (Jurnal Radiografer Indonesia)},
  year = {2018},
  doi = {10.55451/jri.v1i2.20}
}
Kostenlos starten →