EUVIMEDEUVIMED entdecken
Crossref

PERBANDINGAN INFORMASI CITRA ANTARA SEQUENCES T2 FAST FIELD ECHO DAN SUSCEPTIBILITY WEIGHTED IMAGING PADA PEMERIKSAAN MRI BRAIN IRISAN AXIAL DENGAN KASUS MICROBLEEDS

Afandi, 2Luthfi Rusyadi, Fatimah, Jeffry Ardiyanto

JRI (Jurnal Radiografer Indonesia) · 2018

DOI: 10.55451/jri.v1i1.3 ↗

Kurz gefasst

Fachartikel in der Zeitschrift JRI (Jurnal Radiografer Indonesia), 2018. Verfasst von Afandi und 3 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The Gradient echo sequence is a sequence using RF excitation pulse varied and with flip NMV through various angle (Instead of 900). It’s sensitive in detecting the present of hemorrhages that have susceptibility and blooming effect to hemorrhages. T2 fast field echo (T2 FFE) and susceptibility weighted imaging (SWI) are part of the gradient echo pulse sequences, in which T2 FFE sequences is conventional non- steady state imaging 2D milti-slice and SWI is 3D velocity compensated sequence gradient echo. On both the sequence is very good for asses the hemorrhages particularly microbleeds. This study aims to determine differences in image information and determine the most optimal image information between T2 FFE and SWI sequences in brain MRI axial slices with microbleeds cases.

Methods

Type of research is quantitative experimental approach. The data was taken from October to November 2016 at Radiology Installation of Siloam Hospital Lippo Village. The study populations was all examinations brain MRI with the microbleeds cases, 5 samples with inclusion criteria described. Scanning by using T2 FFE and SWI sequences, then evaluation by respondents furthermore the data was processed using kappa test, and analyzing the date using wilcoxon test, and then to get an assesment of the most optimal images seen from the mean rank wilcoxon test.

Results

The result was p-value 0,025 (p

Zitieren

APA

Afandi, Rusyadi, L., Fatimah, & Ardiyanto, J. (2018). PERBANDINGAN INFORMASI CITRA ANTARA SEQUENCES T2 FAST FIELD ECHO DAN SUSCEPTIBILITY WEIGHTED IMAGING PADA PEMERIKSAAN MRI BRAIN IRISAN AXIAL DENGAN KASUS MICROBLEEDS. JRI (Jurnal Radiografer Indonesia). https://doi.org/10.55451/jri.v1i1.3

Vancouver

Afandi, Rusyadi L, Fatimah, Ardiyanto J. PERBANDINGAN INFORMASI CITRA ANTARA SEQUENCES T2 FAST FIELD ECHO DAN SUSCEPTIBILITY WEIGHTED IMAGING PADA PEMERIKSAAN MRI BRAIN IRISAN AXIAL DENGAN KASUS MICROBLEEDS. JRI (Jurnal Radiografer Indonesia). 2018. doi:10.55451/jri.v1i1.3

BibTeX
@article{Afandi2018,
  author = {Afandi and Rusyadi, 2Luthfi and Fatimah and Ardiyanto, Jeffry},
  title = {PERBANDINGAN INFORMASI CITRA ANTARA SEQUENCES T2 FAST FIELD ECHO DAN SUSCEPTIBILITY WEIGHTED IMAGING PADA PEMERIKSAAN MRI BRAIN IRISAN AXIAL DENGAN KASUS MICROBLEEDS},
  journal = {JRI (Jurnal Radiografer Indonesia)},
  year = {2018},
  doi = {10.55451/jri.v1i1.3}
}
Kostenlos starten →