ROTATIONAL MISMATCH OF SELF-ALIGN TIBIAL COMPONENT IN POSTERIOR-STABILIZED (PS) TOTAL KNEE ARTHROPLASTY
Journal of Southeast Asian Medical Research · 2017
DOI: 10.55374/jseamed.v1i2.25 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Southeast Asian Medical Research, 2017. Verfasst von Saradej Khuangsirikul und 3 weiteren Autor:innen. Die Arbeit nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Background
Rotational alignment of femoral and tibial prosthesis is one of the important factors for outcomes of total knee arthroplasty (TKA). Rotational malalignment may lead to patellar maltracking, anterior knee pain, femoro-tibial flexion instability and premature wear of the polyethylene inlay. Several studies have demonstrated higher revision rates and less favorable clinical results among patients with rotational malalignment. The transepicondylar axis is widely accepted as the best representation of the functional flexion-extension axis of the knee. On the other hand, no comparable agreement exists for tibial rotational alignment Objectives: The aim of this study was to determine the accurate rotational alignment of components by posterior cruciate lignment substituting TKA using the center-post self-align technique.
Method
From January 2007 to May 2009, 54 patients (60 knees) underwent the cemented, posterior ligament substituting TKA using the center-post self-align technique of the tibial component and performed computer tomography postoperatively. The rotational angle between the femoral and tibial components and the rotational variance from the transepicondylar axis were measured.
Results
The rotational alignment of femoral components were 90% in the neutral group: 48.3% external rotate (mean 1.15 , range 0.1 – 4.9), 48.3% internal rotate (mean 1.53 , range 0.2 -3.8) and 3.4% were in neutral alignment. The rotation alignment of tibial components were 71.7% in the neutral group: 41.2% external rotate (mean 2.03 , range 0.2 -6.7), 56.7% internal rotate (mean 2.59 , range 0.3 -6.7) and 1.67% had neutral alignment. We found no rotational mismatch between femoral and tibial components in this study. All 60 knees had good patellar tracking by no thumb test technique without lateral released procedure.
Conclusion
Femoral component rotations were mostly in the safe zone. Using the center-post self-align technique in posterior cruciate ligament substiting TKA, tibial component rotation was much more varied than the femur. However, all tibial component rotations were in between medial most and medial 1/3 of the tibial tuberble
Zitieren
APA
Khuangsirikul, S., Choowong, M., Trakulngernthai, S., & Chotanaphuti, T. (2017). ROTATIONAL MISMATCH OF SELF-ALIGN TIBIAL COMPONENT IN POSTERIOR-STABILIZED (PS) TOTAL KNEE ARTHROPLASTY. Journal of Southeast Asian Medical Research. https://doi.org/10.55374/jseamed.v1i2.25
Vancouver
Khuangsirikul S, Choowong M, Trakulngernthai S, Chotanaphuti T. ROTATIONAL MISMATCH OF SELF-ALIGN TIBIAL COMPONENT IN POSTERIOR-STABILIZED (PS) TOTAL KNEE ARTHROPLASTY. Journal of Southeast Asian Medical Research. 2017. doi:10.55374/jseamed.v1i2.25
BibTeX
@article{Khuangsirikul2017,
author = {Khuangsirikul, Saradej and Choowong, Montri and Trakulngernthai, Songpol and Chotanaphuti, Thanainit},
title = {ROTATIONAL MISMATCH OF SELF-ALIGN TIBIAL COMPONENT IN POSTERIOR-STABILIZED (PS) TOTAL KNEE ARTHROPLASTY},
journal = {Journal of Southeast Asian Medical Research},
year = {2017},
doi = {10.55374/jseamed.v1i2.25}
}
EUVIMED