Diastema Closure Using A Removable Orthodontic Appliance With Finger Spring And Labial Arch: Case Report
International Journal of Health Engineering and Technology · 02.11.2026 · 5 (4)
DOI: 10.55227/ijhet.v5i4.1261 ↗Kurz gefasst
Fallbericht in der Zeitschrift International Journal of Health Engineering and Technology, online erschienen am 02.11.2026. Verfasst von Naila Fadhilah Romadhona und 1 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Diastema is a condition characterized by the presence of a space or gap between two adjacent teeth. Diastema closure can be performed using removable orthodontic appliance with active components that deliver forces to the teeth. This case report aimed to describe the management of maxillary midline diastema using a removable orthodontic appliance combining finger springs and a labial arch. A 20-year-old female patient presented to Soelastri Dental Hospital, Surakarta, with complaint of a space between the maxillary anterior teeth affecting her appearance. Clinical examination revealed a midline diastema between teeth 11 and 21, accompanied by anterior tooth malpositions. Treatment was performed using a maxillary plate equipped with finger springs on teeth 11 and 21 and a labial arch with an inverted U-shaped loop. The appliance was activated and progress was evaluated periodically. The midline diastema measured 0.7 mm at appliance insertion, decreased to 0.6 mm at the second follow-up and 0.3 mm at the eighth follow-up, and was completely closed by the tenth follow-up. Overjet decreased from 3 mm to 2.5 mm, while overbite decreased from 3 mm to 2.6 mm. The combination of finger springs and labial arch achieved closure of the maxillary midline diastema with controlled tooth movement.
Zitieren
APA
Romadhona, N. F., & Kurniasari, R. (2026). Diastema Closure Using A Removable Orthodontic Appliance With Finger Spring And Labial Arch: Case Report. International Journal of Health Engineering and Technology, 5(4). https://doi.org/10.55227/ijhet.v5i4.1261
Vancouver
Romadhona NF, Kurniasari R. Diastema Closure Using A Removable Orthodontic Appliance With Finger Spring And Labial Arch: Case Report. International Journal of Health Engineering and Technology. 2026;5(4). doi:10.55227/ijhet.v5i4.1261
BibTeX
@article{Romadhona2026,
author = {Romadhona, Naila Fadhilah and Kurniasari, Reni},
title = {Diastema Closure Using A Removable Orthodontic Appliance With Finger Spring And Labial Arch: Case Report},
journal = {International Journal of Health Engineering and Technology},
year = {2026},
volume = {5},
number = {4},
doi = {10.55227/ijhet.v5i4.1261}
}
EUVIMED