CAPACITY WITHOUT LOAD: A 30-FOLD DENOMINATOR TRAP AND STARTUP ENERGY INTENSITY IN A SEVEN-YEAR KILN PANEL
International Journal of Energy and Smart Grid · 21.11.2026 · 11
DOI: 10.55088/ijesg.2020688 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal of Energy and Smart Grid, online erschienen am 21.11.2026. Verfasst von Syed Syyeduzzaman. Die Arbeit nennt 20 Literaturangaben.
Abstract (Originalsprache)
Specific energy consumption is meaningful only when the energy numerator and production denominator cover the same boundary and period. This archival field study reconstructs 81 monthly observations from January 2016 to December 2022 for the biscuit and glost kilns of an anonymised porcelain tableware manufacturer, combining kiln-loading records, annual factory-performance workbooks and a capacity-expansion plan. Two linked findings provide the contribution. First, cells labelled In Ton in the 2020 and 2021 workbooks calculate average tonnes per day; summing those cells as annual tonnage produces 11,031 and 10,725 m3 of gas per tonne, while reconstructing period tonnes from stored piece counts and the workbook's 0.45 kg-per-piece assumption yields 367.7 and 357.5 m3 per tonne, an exact 30-fold correction. Second, a new glost kiln began reporting gas in March 2022; the plan allocated 688,000 pieces per month to it while its active-month average was 335,897 first-pass pieces, or 48.8% of plan. Its gas intensity was 0.255 m3 per first-pass piece versus 0.192 for the legacy kiln, and combined glost intensity rose from 0.177 to 0.209, a 17.6% increase. The study does not claim a causal technology penalty. It shows how denominator governance and utilisation regime determine what an energy-performance indicator means, and proposes a reproducible control protocol.
Zitieren
APA
Syyeduzzaman, S. (2026). CAPACITY WITHOUT LOAD: A 30-FOLD DENOMINATOR TRAP AND STARTUP ENERGY INTENSITY IN A SEVEN-YEAR KILN PANEL. International Journal of Energy and Smart Grid, 11. https://doi.org/10.55088/ijesg.2020688
Vancouver
Syyeduzzaman S. CAPACITY WITHOUT LOAD: A 30-FOLD DENOMINATOR TRAP AND STARTUP ENERGY INTENSITY IN A SEVEN-YEAR KILN PANEL. International Journal of Energy and Smart Grid. 2026;11. doi:10.55088/ijesg.2020688
BibTeX
@article{Syyeduzzaman2026,
author = {Syyeduzzaman, Syed},
title = {CAPACITY WITHOUT LOAD: A 30-FOLD DENOMINATOR TRAP AND STARTUP ENERGY INTENSITY IN A SEVEN-YEAR KILN PANEL},
journal = {International Journal of Energy and Smart Grid},
year = {2026},
volume = {11},
doi = {10.55088/ijesg.2020688}
}
EUVIMED