Kurz gefasst

Fachartikel in der Zeitschrift Biomedical Papers, online erschienen am 03.11.2026. Verfasst von Ales Prihoda und 2 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Biomedical Engineering, Czech Technical University in Prague, Kladno, Czech Republic. Die Arbeit nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

AIMS: To assess whether adding high-intensity magnetic therapy (HIMT) to robot-assisted gait training (RAGT) with a ReoAmbulator produces greater improvement in spasticity and gait than RAGT with standard inpatient care in chronic stroke patients with residual spasticity. METHODS: We conducted a two-arm quasi-randomised controlled trial (No. EK 24/01), in which 29 of 30 enrolled patients were analysed per protocol. The experimental group (EXP, n=18) received 15 sessions of HIMT applied to the paretic lower limb, starting 1-2 weeks before RAGT, together with 10 RAGT sessions and standard care, whereas the control group (CON, n=11) received 10 RAGT sessions and standard care only. The primary outcomes were the Modified Ashworth Scale (MAS) of knee extensors and plantar flexors and the Timed Up and Go test (TUG), and the secondary outcomes were RAGT walking speed, session duration and distance. Within-group changes were tested with the Wilcoxon signed-rank test, between-group differences in delta values with the Mann-Whitney U test, and effect sizes were quantified using Cohen's d and Cliff's δ. RESULTS: Baseline characteristics were comparable between groups (all P>0.05), and both groups improved in all outcomes (Wilcoxon P ≤0.031). Between-group deltas favoured EXP, with TUG improving by -7.9 vs -4.7 s (P 1.0 for the key outcomes) are consistent with the international literature on the antispastic action of repetitive peripheral magnetic stimulation. Because of the limited sample size and the quasi-randomised design, these results should be regarded as preliminary and require confirmation in a larger randomised controlled trial with long-term follow-up.

Schlagwörter

Stichwörter der Autor:innen

ReoAmbulatorhigh-intensity magnetic therapyrobot-assisted gait trainingspasticitystroke

Autor:innen und Institutionen

  • Faculty of Biomedical Engineering, Czech Technical University in Prague, Kladno, Czech Republic.

Zitieren

APA

Prihoda, A., Wittlerova, K., & Navratil, L. (2026). The effect of high-intensity magnetic therapy combined with robot-assisted gait training in post-stroke patients. Biomedical Papers. https://doi.org/10.5507/bp.2026.031

Vancouver

Prihoda A, Wittlerova K, Navratil L. The effect of high-intensity magnetic therapy combined with robot-assisted gait training in post-stroke patients. Biomedical Papers. 2026. doi:10.5507/bp.2026.031

BibTeX
@article{Prihoda2026,
  author = {Prihoda, Ales and Wittlerova, Kristyna and Navratil, Leos},
  title = {The effect of high-intensity magnetic therapy combined with robot-assisted gait training in post-stroke patients},
  journal = {Biomedical Papers},
  year = {2026},
  doi = {10.5507/bp.2026.031}
}
Kostenlos starten →