EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

An Impact Analysis of Retrofit Shading and Double Skin Facade on Building Performance at the Glass Office of PT Pertamina Patra Niaga - ITJ Jakarta

Sumarno Sumarno, Tigor Wilfritz Soaduon Panjaitan, Andarita Rolalisasi

INTERNATIONAL JOURNAL ON ADVANCED TECHNOLOGY ENGINEERING AND INFORMATION SYSTEM (IJATEIS) · 03.12.2025 · 4 (3) · 482-500

DOI: 10.55047/ijateis.v4i3.2014 ↗

Kurz gefasst

Fachartikel in der Zeitschrift INTERNATIONAL JOURNAL ON ADVANCED TECHNOLOGY ENGINEERING AND INFORMATION SYSTEM (IJATEIS), online erschienen am 03.12.2025. Verfasst von Sumarno Sumarno und 2 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Modern office buildings with glass envelopes often encounter challenges in energy efficiency, particularly due to excessive reliance on artificial lighting during daytime and intensive use of cooling systems. This condition is occurred at the PT Pertamina Patra Niaga - ITJ Jakarta office building. The installation of window films and curtain blinds has made interior spaces darker, preventing optimal utilization of natural daylight and consequently increasing electricity consumption. Such conditions not only reduce energy efficiency but also compromise visual comfort for occupants. This study aims to analyze the impact of retrofit shading and the double skin façade (DSF) on daylighting performance, visual comfort, and energy efficiency. The research employed an existing condition analysis using the Sefaira plug in SketchUp software and Sefaira web model - energyplus to simulate and evaluate the effects of retrofitting on the glass office building. The findings reveal that the integration of retrofit shading and DSF significantly improves natural daylighting quality 2% underlit, 42% well lit, and 44% overlit. Visual comfort was enhanced by lowering indoor illuminance levels of ASE from 87% to 43% lux and sDA from 100% to 98% lux, aligning with recommended standards. Furthermore, annual electricity consumption decreased substantially, from 269 to 130 kWh/m² per year. In conclusion, retrofit shading and DSF provide effective passive design strategies that enhance daylight utilization, improve occupant comfort, and support energy conservation. This study serves as a preliminary investigation for future research on integrating multiple passive design strategies in office building retrofits.

Zitieren

APA

Sumarno, S., Panjaitan, T. W. S., & Rolalisasi, A. (2025). An Impact Analysis of Retrofit Shading and Double Skin Facade on Building Performance at the Glass Office of PT Pertamina Patra Niaga - ITJ Jakarta. INTERNATIONAL JOURNAL ON ADVANCED TECHNOLOGY ENGINEERING AND INFORMATION SYSTEM (IJATEIS), 4(3), 482-500. https://doi.org/10.55047/ijateis.v4i3.2014

Vancouver

Sumarno S, Panjaitan TWS, Rolalisasi A. An Impact Analysis of Retrofit Shading and Double Skin Facade on Building Performance at the Glass Office of PT Pertamina Patra Niaga - ITJ Jakarta. INTERNATIONAL JOURNAL ON ADVANCED TECHNOLOGY ENGINEERING AND INFORMATION SYSTEM (IJATEIS). 2025;4(3):482-500. doi:10.55047/ijateis.v4i3.2014

BibTeX
@article{Sumarno2025,
  author = {Sumarno, Sumarno and Panjaitan, Tigor Wilfritz Soaduon and Rolalisasi, Andarita},
  title = {An Impact Analysis of Retrofit Shading and Double Skin Facade on Building Performance at the Glass Office of PT Pertamina Patra Niaga - ITJ Jakarta},
  journal = {INTERNATIONAL JOURNAL ON ADVANCED TECHNOLOGY ENGINEERING AND INFORMATION SYSTEM (IJATEIS)},
  year = {2025},
  volume = {4},
  number = {3},
  pages = {482--500},
  doi = {10.55047/ijateis.v4i3.2014}
}
Kostenlos starten →