COMPARISON OF THE NUMBER OF ERYTHROCYTES IN 3 ML, 2 ML, & 1 ML OF BLOOD SAMPLES WITH K2EDTA ANTICOAGULANTS AFTER A 4-HOUR DELAY IN THE DR. H. ABDUL MOELOEK BANDAR LAMPUNG HOSPITAL
PHARMACOLOGY, MEDICAL REPORTS, ORTHOPEDIC, AND ILLNESS DETAILS (COMORBID) · 2022
DOI: 10.55047/comorbid.v1i2.144 ↗Kurz gefasst
Fachartikel in der Zeitschrift PHARMACOLOGY, MEDICAL REPORTS, ORTHOPEDIC, AND ILLNESS DETAILS (COMORBID), 2022. Verfasst von Syuhada und 4 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background: The volume of blood samples, especially the number of erythrocytes in laboratory examinations, has an important role in determining the results of the diagnosis, in this case pre-analytic errors often occur so that a definite diagnosis will be difficult to establish. Therefore, research on the comparison between the results of the examination of the number of erythrocytes in the volume of blood samples of 3 mL, 2 mL, and 1 mL after being delayed for 4 hours with K2EDTA anticoagulant helps to determine a definite diagnosis from laboratory tests, one of which is the count of the number of erythrocytes. Research purpose: it aims to identify the comparison of erythrocytes in the volume of blood sample 3 ml, 2 ml, and 1 ml with k2edta anticoagulant after postponed for four hours. Research methods: the study uses primary data with hematology analyzer in rsud Dr.abdul moeloek bandar lampung. This type of research is a quantitative, using observational analtic design with a cross sectional view and with consecutive method, through hematology analysis using a alayzer mindray bc-3600 hematology. The research has 50 respondents. Results: the results of erythrocytes comparison between blood volume 3 ml, 2 ml and 1 ml (ml) with k2edta anticoagulant after 4 hours have different results but statistically the results have the same with 3 ml, that show the lowest result. Conclusion: there is no significant differences between the examunation of the erythrocytes with the volume of blood sample 3 mL, 2 mL, and 1 mL in the vacutainer k2edta tube after postponed for four hours.
Zitieren
APA
Syuhada, Priyayi, H., Putri, B. T., Nabigha, Z. A., & Triwahyuni, T. (2022). COMPARISON OF THE NUMBER OF ERYTHROCYTES IN 3 ML, 2 ML, & 1 ML OF BLOOD SAMPLES WITH K2EDTA ANTICOAGULANTS AFTER A 4-HOUR DELAY IN THE DR. H. ABDUL MOELOEK BANDAR LAMPUNG HOSPITAL. PHARMACOLOGY, MEDICAL REPORTS, ORTHOPEDIC, AND ILLNESS DETAILS (COMORBID). https://doi.org/10.55047/comorbid.v1i2.144
Vancouver
Syuhada, Priyayi H, Putri BT, Nabigha ZA, Triwahyuni T. COMPARISON OF THE NUMBER OF ERYTHROCYTES IN 3 ML, 2 ML, & 1 ML OF BLOOD SAMPLES WITH K2EDTA ANTICOAGULANTS AFTER A 4-HOUR DELAY IN THE DR. H. ABDUL MOELOEK BANDAR LAMPUNG HOSPITAL. PHARMACOLOGY, MEDICAL REPORTS, ORTHOPEDIC, AND ILLNESS DETAILS (COMORBID). 2022. doi:10.55047/comorbid.v1i2.144
BibTeX
@article{Syuhada2022,
author = {Syuhada and Priyayi, Hemas and Putri, Bella Tania and Nabigha, Zehan Aura and Triwahyuni, Tusy},
title = {COMPARISON OF THE NUMBER OF ERYTHROCYTES IN 3 ML, 2 ML, & 1 ML OF BLOOD SAMPLES WITH K2EDTA ANTICOAGULANTS AFTER A 4-HOUR DELAY IN THE DR. H. ABDUL MOELOEK BANDAR LAMPUNG HOSPITAL},
journal = {PHARMACOLOGY, MEDICAL REPORTS, ORTHOPEDIC, AND ILLNESS DETAILS (COMORBID)},
year = {2022},
doi = {10.55047/comorbid.v1i2.144}
}
EUVIMED