Analysis of Elevated Circular and Rectangle Water Tanks according to different Seismic zones of India by using STAAD- Pro: A Review

Ms. Samruddhi C. Sagane, Ms. Pallavi S. Bhule

INTERNATIONAL JOURNAL OF SCIENTIFIC RESEARCH IN ENGINEERING AND MANAGEMENT · 27.04.2026 · 10 (04) · 1-9

DOI: 10.55041/ijsrem61216 ↗

Kurz gefasst

Fachartikel in der Zeitschrift INTERNATIONAL JOURNAL OF SCIENTIFIC RESEARCH IN ENGINEERING AND MANAGEMENT, online erschienen am 27.04.2026. Verfasst von Ms. Samruddhi C. Sagane und 1 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

- Elevated reinforced cement concrete (RCC) water tanks are critical infrastructure components, especially in seismic-prone regions, where their structural integrity directly impacts public safety and service continuity. This review paper synthesizes findings from various studies focusing on the seismic behavior of elevated water tanks with different geometries, capacities, and operating conditions. The analysis highlights the comparative performance of circular and rectangular tanks under varying seismic zones, water filling conditions, and soil types, primarily using STAAD.Pro-based modeling approaches. The reviewed literature indicates that circular tanks consistently demonstrate better seismic resistance due to their uniform geometry, resulting in reduced stress concentrations and lateral displacements. Factors such as tank height, staging configuration, and foundation conditions significantly influence seismic response, with increased height and soft soil conditions amplifying structural demands. Additionally, partially filled tanks are identified as the most critical condition due to asymmetric mass distribution. The review also emphasizes the importance of adhering to design codes and adopting optimized construction practices to enhance durability and performance. Overall, the study underscores the need for integrated design approaches that consider geometric, structural, and operational parameters to ensure the safety and efficiency of elevated water tanks in seismic regions. Keywords: Elevated RCC water tanks, Seismic analysis, STAAD.Pro, Circular vs rectangular tanks, Base shear, Structural stability

Zitieren

APA

Sagane, M. S. C., & Bhule, M. P. S. (2026). Analysis of Elevated Circular and Rectangle Water Tanks according to different Seismic zones of India by using STAAD- Pro: A Review. INTERNATIONAL JOURNAL OF SCIENTIFIC RESEARCH IN ENGINEERING AND MANAGEMENT, 10(04), 1-9. https://doi.org/10.55041/ijsrem61216

Vancouver

Sagane MSC, Bhule MPS. Analysis of Elevated Circular and Rectangle Water Tanks according to different Seismic zones of India by using STAAD- Pro: A Review. INTERNATIONAL JOURNAL OF SCIENTIFIC RESEARCH IN ENGINEERING AND MANAGEMENT. 2026;10(04):1-9. doi:10.55041/ijsrem61216

BibTeX
@article{Sagane2026,
  author = {Sagane, Ms. Samruddhi C. and Bhule, Ms. Pallavi S.},
  title = {Analysis of Elevated Circular and Rectangle Water Tanks according to different Seismic zones of India by using STAAD- Pro: A Review},
  journal = {INTERNATIONAL JOURNAL OF SCIENTIFIC RESEARCH IN ENGINEERING AND MANAGEMENT},
  year = {2026},
  volume = {10},
  number = {04},
  pages = {1--9},
  doi = {10.55041/ijsrem61216}
}
Kostenlos starten →