Abstract (Originalsprache)

High-voltage direct current (HVDC) grids are expanding rapidly as the backbone of long-distance renewable energy transmission, but their low system impedance creates a fault current problem that AC networks, with their natural zero-crossings, do not face in quite the same way. Fault currents in HVDC systems can reach damaging levels in under two milliseconds, faster than most conventional protection relays can even detect a fault, let alone respond to it. Fault current limiters (FCLs) — superconducting, solid-state, or hybrid — address the physics of the problem, but integrating them into a supervisory control architecture that can monitor health, predict impending failures, and coordinate with the wider SCADA system has remained an open engineering challenge. This paper proposes an IoT-based three-layer supervisory control framework for FCL management in HVDC substations, combining IEC 61850 GOOSE messaging at the edge with MQTT-over-TLS telemetry to a cloud SCADA platform and an LSTM-based edge AI module for real-time fault classification. Tested on a ±500 kV HVDC substation hardware-in-the-loop (HIL) testbed, the proposed system detected fault inception in 1.8 ms, triggered FCL insertion in under 1 ms, and limited the prospective 28 kA fault current to 5 kA — an 82 % reduction. End-to-end SCADA latency was 4.2 ms, and system availability over a six-month monitoring period was 99.97 %. The false positive trip rate was 0.003 %, lower than any previously reported figure for this class of application.

Zitieren

APA

Ratnaparkhi, P., More, P., & Sardar, P. P. (2026). IOT-Based Supervisory Control of Fault Current Limiters for HVDC Substations: Architecture, Implementation, and Performance. International Journal of Science, Strategic Management and Technology, 02(05), 1-9. https://doi.org/10.55041/ijsmt.v2i5.309

Vancouver

Ratnaparkhi P, More P, Sardar PP. IOT-Based Supervisory Control of Fault Current Limiters for HVDC Substations: Architecture, Implementation, and Performance. International Journal of Science, Strategic Management and Technology. 2026;02(05):1-9. doi:10.55041/ijsmt.v2i5.309

BibTeX
@article{Ratnaparkhi2026,
  author = {Ratnaparkhi, Prof.S.R . and More, Prof.B.A. and Sardar, Prof P.G.},
  title = {IOT-Based Supervisory Control of Fault Current Limiters for HVDC Substations: Architecture, Implementation, and Performance},
  journal = {International Journal of Science, Strategic Management and Technology},
  year = {2026},
  volume = {02},
  number = {05},
  pages = {1--9},
  doi = {10.55041/ijsmt.v2i5.309}
}
Kostenlos starten →