EUVIMEDEUVIMED entdecken
Crossref

Integrated Net-Zero Energy Design for Hot-Dry Institutional Buildings: A Scenario-Based Energy, Carbon and Cost Assessment for Jaipur, India

Hemant Kumar Agrawal, Anshika Yadav, Ashutosh Luhania

International Journal of Creative and Open Research in Engineering and Management · 25.07.2026 · 02 (07) · 1-9

DOI: 10.55041/ijcope.v2i7.224 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Creative and Open Research in Engineering and Management, online erschienen am 25.07.2026. Verfasst von Hemant Kumar Agrawal und 2 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Net-zero-energy buildings in hot-dry regions must reconcile high cooling demand, limited roof area, grid interaction, embodied carbon and investment constraints. This study develops an integrated design-stage assessment for a four-storey, 6,000 m² institutional building in Jaipur, India. The baseline is aligned with the Energy Conservation and Sustainable Building Code 2024, while the proposed case combines east–west massing, solar control, improved opaque-envelope performance, high-performance glazing, daylight-linked LED lighting, efficient variable-refrigerant-flow cooling, demand-controlled ventilation, plug-load management and a 235 kWp rooftop photovoltaic system. A transparent monthly/end-use energy model is linked to annual and representative hourly energy-balance checks, an A1–A5 embodied-carbon inventory, a 60-year operational carbon model, a 25-year discounted cash-flow analysis and a 5,000-run Monte Carlo uncertainty assessment. The modeled annual site energy decreases from 748.8 to 375.0 MWh, equivalent to an EUI reduction from 124.8 to 62.5 kWh/m²·year. PV generation is 385.4 MWh/year, producing an annual surplus of 10.4 MWh; however, only 68.2% of PV electricity is used directly, so the building still imports 112.3 MWh and exports 122.7 MWh. Upfront embodied carbon falls from 4,030 to 3,050 tCO₂e despite the PV addition, primarily through lower-carbon concrete and recycled-content steel. Under a 2.5% annual grid-decarbonization trajectory, whole-life carbon falls by 73–86%, depending on whether exported electricity is credited. The ₹31.9 million incremental investment has a 5.8-year simple payback, an 8-year discounted payback, a 20.1% internal rate of return and a ₹46.4 million NPV. The study shows that annual net zero is technically and economically plausible for the selected archetype, but robust delivery requires explicit PV margin, commissioning, plug-load governance and post-occupancy verification. Keywords: net-zero energy building; sustainable construction; hot-dry climate; ECSBC 2024; rooftop photovoltaics; embodied carbon; life-cycle cost; uncertainty analysis; Jaipur

Zitieren

APA

Agrawal, H. K., Yadav, A., & Luhania, A. (2026). Integrated Net-Zero Energy Design for Hot-Dry Institutional Buildings: A Scenario-Based Energy, Carbon and Cost Assessment for Jaipur, India. International Journal of Creative and Open Research in Engineering and Management, 02(07), 1-9. https://doi.org/10.55041/ijcope.v2i7.224

Vancouver

Agrawal HK, Yadav A, Luhania A. Integrated Net-Zero Energy Design for Hot-Dry Institutional Buildings: A Scenario-Based Energy, Carbon and Cost Assessment for Jaipur, India. International Journal of Creative and Open Research in Engineering and Management. 2026;02(07):1-9. doi:10.55041/ijcope.v2i7.224

BibTeX
@article{Agrawal2026,
  author = {Agrawal, Hemant Kumar and Yadav, Anshika and Luhania, Ashutosh},
  title = {Integrated Net-Zero Energy Design for Hot-Dry Institutional Buildings: A Scenario-Based Energy, Carbon and Cost Assessment for Jaipur, India},
  journal = {International Journal of Creative and Open Research in Engineering and Management},
  year = {2026},
  volume = {02},
  number = {07},
  pages = {1--9},
  doi = {10.55041/ijcope.v2i7.224}
}
Kostenlos starten →