EUVIMEDEUVIMED entdecken
Crossref

Effects of Concrete filled Steel tubular sections on seismic response of multistoried building

Sarjerao Patil Sarjerao Patil, Priyanka samadhan Jadhav Priyanka samadhan Jadhav

International Journal of Creative and Open Research in Engineering and Management · 28.06.2026 · 02 (06) · 1-11

DOI: 10.55041/ijcope.v2i5.490 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Creative and Open Research in Engineering and Management, online erschienen am 28.06.2026. Verfasst von Sarjerao Patil Sarjerao Patil und 1 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The increasing growth of urban infrastructure and rising awareness regarding earthquake safety have created a strong demand for durable, economical, and earthquake-resistant multistorey buildings. Reinforced cement concrete (RCC) framed structures have traditionally been the most widely adopted construction system because of their simplicity, availability of materials, and cost-effectiveness. However, conventional RCC structures may experience limitations in terms of ductility, seismic energy dissipation, and post-earthquake structural recovery, especially in regions subjected to strong seismic activity. To overcome these challenges, composite structural systems such as Concrete-Filled Steel Tubular (CFST) members have emerged as an efficient alternative for seismic-resistant construction. CFST members consist of hollow steel tubes filled with concrete, combining the advantageous properties of both materials into a single structural element. The steel tube provides tensile strength, confinement, and enhanced ductility, while the concrete core contributes compressive strength, stiffness, and improved fire resistance. Due to this composite interaction, CFST members demonstrate superior structural efficiency and seismic performance compared to conventional RCC members. When incorporated into multistorey buildings as columns or lateral load-resisting components, CFST systems can significantly influence important dynamic characteristics such as natural time period, stiffness distribution, modal behavior, and overall seismic response. Consequently, parameters including lateral displacement, storey drift, base shear, storey shear, time period, and storey stiffness are directly affected by the adoption of CFST members.

Zitieren

APA

Patil, S. P. S., & Jadhav, P. S. J. P. S. (2026). Effects of Concrete filled Steel tubular sections on seismic response of multistoried building. International Journal of Creative and Open Research in Engineering and Management, 02(06), 1-11. https://doi.org/10.55041/ijcope.v2i5.490

Vancouver

Patil SPS, Jadhav PSJPS. Effects of Concrete filled Steel tubular sections on seismic response of multistoried building. International Journal of Creative and Open Research in Engineering and Management. 2026;02(06):1-11. doi:10.55041/ijcope.v2i5.490

BibTeX
@article{Patil2026,
  author = {Patil, Sarjerao Patil Sarjerao and Jadhav, Priyanka samadhan Jadhav Priyanka samadhan},
  title = {Effects of Concrete filled Steel tubular sections on seismic response of multistoried building},
  journal = {International Journal of Creative and Open Research in Engineering and Management},
  year = {2026},
  volume = {02},
  number = {06},
  pages = {1--11},
  doi = {10.55041/ijcope.v2i5.490}
}
Kostenlos starten →