Evaluation of Natural Ventilation Influence on Indoor Air Quality in Small Academic Rooms using an IOT-Based Monitoring System
International Journal of Creative and Open Research in Engineering and Management · 14.05.2026 · 02 (05) · 1-9
DOI: 10.55041/ijcope.v2i5.423 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal of Creative and Open Research in Engineering and Management, online erschienen am 14.05.2026. Verfasst von MADHU SUDHAN S und 2 weiteren Autor:innen.
Abstract (Originalsprache)
Indoor air quality (IAQ) in academic environments has gained critical importance due to its direct implications on student cognitive performance, health, and well-being. Small academic rooms, characterized by limited floor area, high occupant density, and constrained architectural configurations, present unique challenges for maintaining adequate air quality through natural ventilation alone. This study presents a comprehensive evaluation of natural ventilation influence on indoor air quality parameters within small academic rooms at an Indian university campus, employing a custom-designed Internet of Things (IoT)-based real-time monitoring system. A network of low-cost, calibrated multi-parameter sensor nodes was deployed across twelve classrooms of varying orientations, window-to-floor-area ratios (WFR: 0.08 to 0.22), and occupancy levels (15 to 45 students). Each node continuously measured carbon dioxide (CO2, ppm), particulate matter (PM2.5 and PM10, ug/m3), temperature (degC), relative humidity (%), volatile organic compounds (VOC, ppb), and formaldehyde (HCHO, ug/m3) at one-minute intervals over a monitoring period of nine months spanning all three climatic seasons (winter, summer, and monsoon). Results indicate that CO2 concentrations exceeded the ASHRAE 62.1 threshold of 1000 ppm during 68.4% of occupied hours in rooms with WFR below 0.12 and adverse wind conditions. PM2.5 levels surpassed the WHO 24-hour guideline of 15 ug/m3 in 54.2% of monitored sessions during the pre-monsoon season, attributable to outdoor particulate infiltration through open windows. Rooms with cross-ventilation configurations demonstrated 34.7% lower mean CO2 concentrations compared to single-sided ventilation arrangements. Occupancy density emerged as the strongest predictor of CO2 accumulation (R2 = 0.87), followed by wind speed (R2 = 0.73) and window opening area (R2 = 0.68). Regression models and machine learning classifiers (Random Forest, AUC = 0.94) were developed to predict IAQ category (Good/Moderate/Poor) using environmental and architectural input parameters. The IoT system demonstrated a mean absolute error (MAE) of 28.4 ppm for CO2 prediction and 1.8 ug/m3 for PM2.5 estimation after field calibration against reference instruments. Findings highlight critical deficiencies in current natural ventilation practices and provide evidence-based recommendations for window design, occupancy scheduling, and supplementary mechanical ventilation strategies. This research contributes directly to sustainable building design and healthy learning environment policy in tropical climate zones.
Zitieren
APA
S, M. S., M, A. K., & J, G. (2026). Evaluation of Natural Ventilation Influence on Indoor Air Quality in Small Academic Rooms using an IOT-Based Monitoring System. International Journal of Creative and Open Research in Engineering and Management, 02(05), 1-9. https://doi.org/10.55041/ijcope.v2i5.423
Vancouver
S MS, M AK, J G. Evaluation of Natural Ventilation Influence on Indoor Air Quality in Small Academic Rooms using an IOT-Based Monitoring System. International Journal of Creative and Open Research in Engineering and Management. 2026;02(05):1-9. doi:10.55041/ijcope.v2i5.423
BibTeX
@article{S2026,
author = {S, MADHU SUDHAN and M, AJITH KUMAR and J, GARKEYA},
title = {Evaluation of Natural Ventilation Influence on Indoor Air Quality in Small Academic Rooms using an IOT-Based Monitoring System},
journal = {International Journal of Creative and Open Research in Engineering and Management},
year = {2026},
volume = {02},
number = {05},
pages = {1--9},
doi = {10.55041/ijcope.v2i5.423}
}