EUVIMEDEUVIMED entdecken
QuerschnittstudieOpen Access · CC BY 4.0

Critical Shoulder Angle Measurement Accuracy in Magnetic Resonance Imaging versus Radiographs: A retrospective cross-sectional study

Salha Albahkali, Afrah Alanazi, Aliya Alawaji, Iba Alfawaz, Ahmad Aljefri, Leena Kattan, Salem Bauones

Saudi Journal of Radiology · 2025

DOI: 10.55038/jz0npt70 ↗

Kurz gefasst

Querschnittstudie in der Zeitschrift Saudi Journal of Radiology, 2025. Verfasst von Salha Albahkali und 6 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The Critical Shoulder Angle (CSA) is a radiographic measurement that has proven valuable in assessing shoulder pathologies such as osteoarthritis and rotator cuff tears. Despite its clinical utility, the consistency of CSA measurements across different imaging modalities, particularly magnetic resonance imaging (MRI) versus radiographs, remains debated.

Objective

This retrospective cross-sectional study aims to assess the accuracy and reliability of CSA measurements obtained from routine shoulder MRI compared to standard radiography.

Methods

A total of 210 patients with both coronal oblique MRI images and true anteroposterior (AP) radiographs of the shoulder were included in the study. CSA measurements were independently performed by two observers using a standardized method, and inter- and intra-observer agreement was evaluated. Statistical analyses were conducted to determine differences in CSA measurements between the two modalities and assess agreement levels.

Results

The mean CSA measured on radiographs (33.7 ± 4.4) was significantly higher than that on MRI (32.8 ± 4.06, p=0.04). Inter- and intra-observer agreements were higher for radiographic measurements (ICC > 0.95) compared to MRI, where variability was noted, particularly concerning gender differences. CSA values showed no significant differences based on shoulder side (right vs. left) in either modality.

Conclusion

CSA measurements were more accurate and consistent on radiographs than MRI, suggesting that radiography remains the preferred modality for assessing CSA in clinical settings. The study highlights the need for standardized imaging techniques to improve measurement consistency across modalities.

Zitieren

APA

Albahkali, S., Alanazi, A., Alawaji, A., Alfawaz, I., Aljefri, A., Kattan, L., & Bauones, S. (2025). Critical Shoulder Angle Measurement Accuracy in Magnetic Resonance Imaging versus Radiographs: A retrospective cross-sectional study. Saudi Journal of Radiology. https://doi.org/10.55038/jz0npt70

Vancouver

Albahkali S, Alanazi A, Alawaji A, Alfawaz I, Aljefri A, Kattan L, et al. Critical Shoulder Angle Measurement Accuracy in Magnetic Resonance Imaging versus Radiographs: A retrospective cross-sectional study. Saudi Journal of Radiology. 2025. doi:10.55038/jz0npt70

BibTeX
@article{Albahkali2025,
  author = {Albahkali, Salha and Alanazi, Afrah and Alawaji, Aliya and Alfawaz, Iba and Aljefri, Ahmad and Kattan, Leena and Bauones, Salem},
  title = {Critical Shoulder Angle Measurement Accuracy in Magnetic Resonance Imaging versus Radiographs: A retrospective cross-sectional study},
  journal = {Saudi Journal of Radiology},
  year = {2025},
  doi = {10.55038/jz0npt70}
}
Kostenlos starten →