EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Mechanical and chemical properties of contemporary composite resins cured with different light-curing units

Rafaella Calixto Vieira Praes, Adriana da Silva Torres, Cíntia Tereza Pimenta de Araújo, Carlos Enrique Cuevas Suárez, Dhelfeson Willya Douglas de Oliveira, Cristina Pereira Isolan

Revista DCS · 06.08.2026 · 23 (93) · e6197

DOI: 10.54899/dcs.v23i93.6197 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Revista DCS, online erschienen am 06.08.2026. Verfasst von Rafaella Calixto Vieira Praes und 5 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Composite resins require photoinitiators activated by light-curing units, and their effectiveness varies with monowave or multiwave devices. Different systems can influence polymerization and mechanical properties. The objective of this study was to evaluate the effects on the mechanical and chemical properties of composite resins (CRs) containing alternative photoinitiators cured by two different light-curing units (LCUs), monowave and multiwave. In this in vitro study, six CRs were divided and evaluated in two groups, monowave (Mono) and multiwave (Multi) photoactivated with irradiance of 1.000 mW/cm2 for 20 seconds. The flexural strength was evaluated through the three-point bending test with a Universal Testing Machine, after 24 h and six months of storage. The microhardness was measured on the surface by Knoop hardness, and the degree of conversion by Fourier Transform Infrared Spectroscopy. The data were analyzed by the T Student and one-way ANOVA test with a significance level of α=0.05. Flexural strength showed statistically significant differences (p < 0.05) in all composite resins, with higher values observed when the multiwave LCU was used. Regarding microhardness, statistically lower values were observed only for IPS Empress Direct and Palfique LX5 when cured with the multiwave LCU. For the degree of conversion, only IPS Empress Direct showed significantly lower values with the multiwave device. In this study multiwave LCU was associated with higher flexural strength values under the conditions evaluated.

Zitieren

APA

Praes, R. C. V., Torres, A. D. S., Araújo, C. T. P. D., Suárez, C. E. C., Oliveira, D. W. D. D., & Isolan, C. P. (2026). Mechanical and chemical properties of contemporary composite resins cured with different light-curing units. Revista DCS, 23(93), e6197. https://doi.org/10.54899/dcs.v23i93.6197

Vancouver

Praes RCV, Torres ADS, Araújo CTPD, Suárez CEC, Oliveira DWDD, Isolan CP. Mechanical and chemical properties of contemporary composite resins cured with different light-curing units. Revista DCS. 2026;23(93):e6197. doi:10.54899/dcs.v23i93.6197

BibTeX
@article{Praes2026,
  author = {Praes, Rafaella Calixto Vieira and Torres, Adriana da Silva and Araújo, Cíntia Tereza Pimenta de and Suárez, Carlos Enrique Cuevas and Oliveira, Dhelfeson Willya Douglas de and Isolan, Cristina Pereira},
  title = {Mechanical and chemical properties of contemporary composite resins cured with different light-curing units},
  journal = {Revista DCS},
  year = {2026},
  volume = {23},
  number = {93},
  pages = {e6197},
  doi = {10.54899/dcs.v23i93.6197}
}
Kostenlos starten →