Thermal Analysis of a Hollow-Shaft Water-Cooled Permanent-Magnet Motor
Frontiers in Science and Engineering · 20.11.2026 · 6 (11) · 12-25
DOI: 10.54691/k5zz0848 ↗Kurz gefasst
Fachartikel in der Zeitschrift Frontiers in Science and Engineering, online erschienen am 20.11.2026. Verfasst von Wenzheng Liu. Die Arbeit nennt 15 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
With the increasing demand for compact, high-power-density underwater propulsion systems, heat dissipation in permanent-magnet motors has become an increasingly important issue, and cooling performance directly affects motor service life and operational safety. Conventional approaches, including housing water jackets, air cooling, and hybrid cooling, may involve long heat-transfer paths, structural redundancy, or limited cooling capacity. This study proposes an internal cooling structure based on a hollow shaft, integrating the coolant passage with the rotor shaft system to shorten the rotor-side heat-transfer path while improving heat dissipation and maintaining compactness and engineering applicability. Computational fluid dynamics (CFD) is used to calculate the temperature fields of a permanent-magnet motor with different water-channel configurations under rated operating conditions. The results show that the smooth axial channel provides better overall hydraulic and thermal performance than the helical channel: its maximum temperature is 26.24 °C, compared with 27.04 °C for the helical channel, while the maximum inlet–outlet pressure difference decreases from 1058 Pa to 163 Pa. With a 50-mm hollow-shaft cooling channel, the maximum temperatures of the stator core, winding, permanent magnet, and shaft are 63.34 °C, 68.03 °C, 30.86 °C, and 34.25 °C, respectively, substantially below those of the solid-shaft baseline, in which all key components exceed 247 °C. These results indicate that a hollow-shaft cooling design with a smooth axial channel can improve heat removal from the rotor region and reduce the risk of permanent-magnet overheating under the investigated conditions.
Zitieren
APA
Liu, W. (2026). Thermal Analysis of a Hollow-Shaft Water-Cooled Permanent-Magnet Motor. Frontiers in Science and Engineering, 6(11), 12-25. https://doi.org/10.54691/k5zz0848
Vancouver
Liu W. Thermal Analysis of a Hollow-Shaft Water-Cooled Permanent-Magnet Motor. Frontiers in Science and Engineering. 2026;6(11):12-25. doi:10.54691/k5zz0848
BibTeX
@article{Liu2026,
author = {Liu, Wenzheng},
title = {Thermal Analysis of a Hollow-Shaft Water-Cooled Permanent-Magnet Motor},
journal = {Frontiers in Science and Engineering},
year = {2026},
volume = {6},
number = {11},
pages = {12--25},
doi = {10.54691/k5zz0848}
}
EUVIMED