EUVIMEDEUVIMED entdecken
Crossref

Biofilm Production Among Clinical Staphylococcus Isolates: A Comparison of Three Laboratory Detection Methods

Devikrishna S, Pradeep Kumar M, Smitha Pious Francis

ICME JOURNAL OF LABORATORY MEDICINE · 2026 · 25-27

DOI: 10.54646/icme.2026.21 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ICME JOURNAL OF LABORATORY MEDICINE, 2026. Verfasst von Devikrishna S und 2 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Biofilm production is an important virulence factor of Staphylococcus species, contributing to persistent infections, antimicrobial resistance, and reduced susceptibility to conventional antimicrobial treatment. Accurate detection of biofilm production is therefore important in clinical microbiology laboratories. However, the performance of different phenotypic methods may vary.

Objective

To estimate the proportion of biofilm production among clinical Staphylococcus isolates and detection by Congo red agar, the Christensen tube method, and the crystal violet microtiter plate assay.

Methods

This hospital-based cross-sectional study included 110 consecutive eligible Staphylococcus isolates collected at Government Medical College, Thiruvananthapuram, from 20 March 2025 to 19 March 2026. Isolates were identified using conventional laboratory methods, with MALDI-TOF mass spectrometry used for species identification or confirmation. Biofilm production was assessed by three methods.

Results

Staphylococcus aureus was the predominant species among the 110 clinical Staphylococcus isolates, accounting for 78 isolates (70.9%). Biofilm production was detected using three phenotypic methods, with varying positivity rates. The Crystal Violet Microtiter Plate Assay identified the highest number of biofilm-producing isolates, with 62/110 isolates (56.4%) testing positive. In comparison, the Crystal Violet Tube Method detected biofilm production in 35/110 isolates (31.8%), while the Congo Red Agar (CRA) method identified 23/110 isolates (20.9%). Using the Crystal Violet Microtiter Plate Assay as the comparator, the count-based detection estimates for the tube method and CRA were 56.5% and 37.1%, respectively. These findings indicate that the microtiter plate assay detected a greater proportion of biofilm-producing isolates than either of the other two methods.

Conclusion

The crystal violet microtiter plate assay detected the highest proportion of biofilm-positive isolates in this collection.

Zitieren

APA

S, D., M, P. K., & Francis, S. P. (2026). Biofilm Production Among Clinical Staphylococcus Isolates: A Comparison of Three Laboratory Detection Methods. ICME JOURNAL OF LABORATORY MEDICINE, 25-27. https://doi.org/10.54646/icme.2026.21

Vancouver

S D, M PK, Francis SP. Biofilm Production Among Clinical Staphylococcus Isolates: A Comparison of Three Laboratory Detection Methods. ICME JOURNAL OF LABORATORY MEDICINE. 2026:25-27. doi:10.54646/icme.2026.21

BibTeX
@article{S2026,
  author = {S, Devikrishna and M, Pradeep Kumar and Francis, Smitha Pious},
  title = {Biofilm Production Among Clinical Staphylococcus Isolates: A Comparison of Three Laboratory Detection Methods},
  journal = {ICME JOURNAL OF LABORATORY MEDICINE},
  year = {2026},
  pages = {25--27},
  doi = {10.54646/icme.2026.21}
}
Kostenlos starten →